Desa LDL3924NR Owner's Operation And Installation Manual page 11

Unvented (vent-free) gas log heater. 24 inch and 30 inch remote-ready models
Table of Contents

Advertisement

INSTALLATION
NOTICE: Surface temperatures of
adjacent walls and mantels be-
come hot during operation. Walls
and mantels above the firebox
may become hot to the touch. If
installed properly, these tem-
peratures meet the requirement
of the national product standard.
Follow all minimum clearances
shown in this manual.
NOTICE: If your installation does
not meet the minimum clear-
ances shown, you must do one
of the following:
• operate the logs only with the
flue damper open
• raise the mantel to an accept-
able height
• remove the mantel
FLOOR CLEARANCES
A. If installing appliance on the floor level, you
must maintain the minimum distance of 14"
to combustibles (see Figure 8).
B. If combustible materials are less than 14 to the
fireplace, you must install appliance at least 5
above the combustible flooring (see Figure 9).
Figure 8 - Minimum Fireplace Clearances If
Installed at Floor Level
Figure 9 - Minimum Fireplace Clearances
Above Combustible Flooring
Available from Allparts Equipment and Accessories - 1-877-475-5660 - www.allpartsinc.com
Continued
Combustible
Material
14"
Min.
Noncombustible Material
Hearth
Combustible
Material
5"
Min.
INSTALLING DAMPER CLAMP
ACCESSORY FOR VENTED
OPERATION
Note: When used as a vented heater, appliance
must be installed only in a solid-fuel burning
fireplace with a working flue and constructed of
noncombustible material.
You may use this heater as a vented product. There
are three reasons for operating your heater in the
vented mode.
1. The fireplace does not meet the clearance to com-
bustibles requirements for vent-free operation.
2. State or local codes do not permit vent-free
operation.
3. You prefer vented operation.
If reasons number 1 or 2 above apply to you, you
must permanently open chimney flue damper. You
must install the damper clamp accessory (to order,
see Accessories, page 31). This will insure vented
operation (see Figure 10). The damper clamp will
keep damper open. Installation instructions are
included with clamp accessory.
See chart below for minimum permanent flue
opening you must provide. Attach damper clamp
so the minimum permanent flue opening will be
maintained at all times.
AREA OF VARIOUS STANDARD
ROUND FLUES
Diameter
5"
"
7"
8"
Chimney
Minimum Permanent
Height
' to 15'
15' to 30'
Damper
Clamp
Damper
Clamp
Damper
Masonry Fireplace
Figure 10 - Attaching Damper Clamp
Area
0 sq. inches
 sq. inches
3 sq. inches
51 sq. inches
Flue Opening
3 sq. inches
 sq. inches
Damper
Damper
Manufactured
Fireplace

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ldl3924prLdl3930nrLdl3930pr

Table of Contents