Reset Menu - Mastervolt MASTERLINK MICC User Manual

Mass inverter charger control
Table of Contents

Advertisement

recalculated automatically by the Masterlink
MICC every time the battery makes a cycle. The
calculated value is checked with the C.E.F. as
stored in the memory of the Masterlink MICC. If
the calculated value is differs from the stored
value,
only
50%
compensated. This is to avoid the C.E.F. being
changed too much by incorrect wrong settings
or an incorrect calculation of the MICC. For an
accurate
calculation
Masterlink MICC needs approx. 6-10 cycles
after power up.
If the C.E.F. of the battery is known, the C.E.F.
can be set manually to give an accurate reading
directly after power-up of the MICC, but even if
the C.E.F. is set manually, the Masterlink MICC
continues to calculate the C.E.F. and will
automatically adjust it if necessary.
The C.E.F. can be set by means of the Set-up
button between 70 and 90 %. The factory
default is set at 90 %.
Note: If the Select button is held for
five seconds, the arrow in the right part
of the display will change. If the arrow is
pointing downwards ( ) the set value
can be decreased by means of the Set-
up button. If the arrow is pointing
upwards ( ) the set value can be
increased.
Return to users menu (A10)
EXIT LEVEL
Select
->PRESS SET-UP
If this level is entered you can return to the user
menu by means of the Set-up button.

10.3 Reset menu

The reset menu is used to reset the Masterlink
MICC to its factory settings and to reset all
historical data.
Select
Set-up
November 2004 / Masterlink MICC / EN
of
the
difference
of
the
C.E.F.,
This menu can be entered by and holding the
Select and Set-up buttons simultaneously for
five seconds until the Set-up and Select LED's
flash.
is
Return to the factory default settings (F06)
the
Set-up
Now press the Set-up button to enter the menu
With the first level of the reset menu the MICC
can be returned to the factory settings by
holding the Set-up button for 5 seconds.
Resetting the historical data (F07)
Select
If new batteries are installed, the historical data
of the old batteries needs to be erased to leave
only historical data from the newly installed
batteries. By holding the Set-up button for
5 seconds the old data will be erased and a new
cycle for historical data will be started.
Return to users menu (F08)
Select
If this level is entered you can return to the user
menu by means of the Set-up button.
RESET FACTORY
PRESS SET 5sec
RESET HISTORY
PRESS SET 5sec
EXIT LEVEL
->PRESS SET-UP