10-3-4.Outdoor low pressure and outdoor unit current
1. 07-class unit in single operation (OUTDOOR UNIT : MXZ-32RV)
NOTO:The unit of pressure has been changed to MPa on the international system of units(SI unit system).
The converted score against the traditional unit system can be gotten according to the formula below.
(1) COOL operation
1Both indoor and outdoor units are under the same
temperature/humidity condition.
Dry-bulb temperature(°C)
20
25
30
2Air flow speed : HI
3Inverter output frequency : 58Hz
(kgf/F• G)
(MPa•G)
0.6
6
0.5
5
0.4
4
0.3
3
0.2
2
(2) HEAT operation
Indoor
DB(°C)
20.0
WB(°C)
14.5
Set air flow to Hi speed.
Inverter output frequency is 40Hz.
1(MPa • G) =10.2(kgf/f
f • G)
Relative humidity(%)
50
60
70
58Hz
18 20
25
30 32(
50
60
70
Ambient temperature(
/ Ambient humidity(%)
Outdoor
DB(°C)
WB(°C)
<How to work fixed-frequency operation>
1.Set emergency switch to COOL or HEAT.The switch is locat-
ed on indoor unit.
2.Press emergency run ON/OFF button.
3.Compressor starts running at 58Hz (COOL) or 40Hz (HEAT).
4.Indoor fan runs at HI speed and continues for 30 minutes.
5.To cancel this operation,press emergency run ON/OFF button
or any button on remote controller.
11
10
9
8
7
6
o
C)
18 20
(%)
o
C)
2
7
15
20.0
1
6
12
14.5
10
9
8
7
6
2
Ambient temperature(
57
58Hz
25
30 32(
50
60
70
Ambient temperature(
/ Ambient humidity(%)
40Hz
5
10
15
o
C)
o
C)
(%)
o
C)
20

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents