Mitsubishi Electric MSC-07RV Service Manual page 36

Wireless / multi system / inverter controlled multi system type, split-type / heat pump air conditioners
Hide thumbs Also See for MSC-07RV:
Table of Contents

Advertisement

MSC-07RV -
E1
MSC-09RV -
E1
INDOOR UNIT
Indoor coil
Indoor
thermistor
heat
RT12
exchanger
Room temperature
thermistor
RT11
MSC-12RV -
E1
INDOOR UNIT
Indoor
Indoor coil
heat
thermistor
exchanger
RT12
Room temperature
thermistor
RT11
Refrigerant pipe [ 9.52
(Option)
(with heat insulator)
Stop valve
(with service
port)
Flared connection
Flared connection
Stop valve
Refrigerant pipe [6.35
(Option)
(with heat insulator)
Refrigerant pipe [12.7
(Option)
(with heat insulator)
Stop valve
(with service port)
Flared connection
Flared connection
Stop valve
Refrigerant pipe [6.35
(Option)
(with heat insulator)
Reversing valve
Muffler
Strainer
Accumulator
Compressor
Capillary tube
[3.0x[1.6x600(MUH-07RV)
[3.0x[1.6x400(MUH-09RV)
Check valve
Strainer
Capillary tube
[3.0x[1.4x600(MUH-07RV)
[3.0x[1.4x550(MUH-09RV)
Reversing valve
Muffler
Strainer
Accumulator
Compressor
Capillary tube
[3.0x[1.6x700
Strainer
Check
valve
36
MUH-07RV -
MUH-09RV -
OUTDOOR UNIT
Defrost
thermistor
Outdoor
RT61
heat
exchanger
Capillary tube
[3.0x[1.4x800
Reversing valve coil
heating ON
cooling OFF
Refrigerant flow in cooling
Refrigerant flow in heating
MUH-12RV -
OUTDOOR UNIT
Defrost
Outdoor
thermistor
heat
RT61
exchanger
Capillary tube
[3.0x[1.4x500(2pcs)
Capillary tube
[3.0x[1.8x300
Reversing valve coil
heating ON
cooling OFF
Refrigerant flow in cooling
Refrigerant flow in heating
Unit:mm
E1
E1
(2 pcs)
Unit:mm
E1

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents