Overview and Specifications

Ratings/Specifications

The model names of the F3SJ-B contain the 4 digits indicating the protective height (mm).
Item
Detection capability
Beam gap
Number of beams
Protective height
Lens diameter
Operating range
Response time
Startup waiting time
Power supply voltage (Vs)
Current consumption
Light source
Effective aperture angle (EAA)
Safety output (OSSD)
Auxiliary output
Output operation mode
Input voltage
Overvoltage category
Indicator
Mutual interference prevention function
Series connection function
Test function
*1. The load inductance is the maximum value when the safety output frequently repeats ON and OFF. When you use the safety
output at 4 Hz or less, the usable load inductance becomes larger.
*2. These values must be taken into consideration when connecting elements including a capacitive load such as a capacitor.
*3. The Vs indicates a voltage value in your environment.
F3SJ-B
6
User's Manual
Model
Opaque objects
25 mm diameter
20 mm
8 to 102
185 to 2,065 mm
5 mm
0.2 to 7 m
ON to OFF: 15 ms max. (Response time when used alone or in 2 or 3 connected)
OFF to ON: 70 ms max. (Response time when used alone or in 2 or 3 connected)
2 s max.
SELV/PELV 24 VDC±20% (ripple p-p 10% max.)
Refer to "Model/Current Consumption List" on page 8.
Infrared LED (870 nm wavelength)
Based on IEC 61496-2.
Within ±2.5° for both emitter and receiver at an operating range of 3 meters or more.
Two NPN transistor outputs, Load current: 200 mA max., Residual voltage: 2 V max.
(except for voltage drop due to cable extension), Leakage current: 1 mA max., Load
inductance: 2.2 H max. *1
Maximum capacitive load: 1 µF *2
One NPN transistor output
Load current: 100 mA max.
Residual voltage: 2 V max.(except for voltage drop due to cable extension)
Leakage current: 1 mA max.
Safety output: On when receiving light
Auxiliary output: Reverse output of safety output
Test input:
ON voltage: 1/2 Vs to Vs, or open *3 (short circuit current: approx. 3.0 mA)
OFF voltage: 0 V to 3 V (short circuit current: approx. 4.0 mA)
Reset input:
ON voltage: 0 V to 3 V (short circuit current: approx. 4.0 mA)
OFF voltage: 1/2 V to Vs, or open *3 (short circuit current: approx. 3.0 mA)
II (IEC 60664-1)
Refer to "Internal (LED) Indicator Display Pattern" on page 4.
Mutual interference prevention algorithm prevents interference in up to three sets.
Number of connections: Up to three sets
Total number of beams: Up to 192
Maximum connection cable length: 7 m (connection cable (F39-JBR2W) and F3SJ's
cable are not included)
Self-test (at power-on, and during operation)
External test (light emission stop function by test input)
F3SJ-BN25-01T