Safety Precautions; Maintenance Precautions - Mitsubishi Electric FX3GE-24M series Hardware Manual

Melsec-f fx3ge series
Hide thumbs Also See for FX3GE-24M series:
Table of Contents

Advertisement

JY997D49401H
1/2
FX
Series
3GE
Programmable Controller
HARDWARE MANUAL
Manual Number
JY997D49401
Revision
H
Date
December 2017
This manual describes the part names, dimensions, mounting, and specifications
of the product. Before use, read this manual and the manuals of all relevant
products fully to acquire proficiency in handling and operating the product. Make
sure to learn all the product information, safety information, and precautions.
Store this manual in a safe place so that it can be taken out and read whenever
necessary. Always forward it to the end user.
Registration
Ethernet is a trademark of Xerox Corporation.
Phillips is a registered trademark of Phillips Screw Company.
The company and product names described in this manual are registered
trademarks or the trademarks of their respective companies.
Effective December 2017
Specifications are subject to change without notice.
©
2013 Mitsubishi Electric Corporation

Safety Precautions

(Read these precautions before use.)
If the equipment is used in a manner not specified by the manufacturer, the
protection provided by the equipment may be impaired.
This manual classifies the safety precautions into two categories:
and
.
Indicates that incorrect handling may cause hazardous
conditions, resulting in death or severe injury.
Indicates that incorrect handling may cause hazardous
conditions, resulting in medium or slight personal injury
or physical damage.
Depending on the circumstances, procedures indicated by
cause severe injury.
It is important to follow all precautions for personal safety.
STARTUP AND
MAINTENANCE
PRECAUTIONS
• Do not touch any terminal while the PLC's power is on.
Doing so may cause electric shock or malfunctions.
• Before cleaning or retightening terminals, cut off all phases of the power
supply externally.
Failure to do so may cause electric shock.
• This product shall be powered by a UL Listed or Recognized 24 V DC
isolating source when the DC power supply type product is powered by a
power supply converted from hazardous voltages.
• Use the battery for memory backup correctly in conformance to FX
User's Manual - Hardware Edition.
- Use the battery only for the specified purpose.
- Connect the battery correctly.
- Do not charge, disassemble, heat, put in fire, short-circuit, connect
reversely, weld, swallow or burn the battery, or apply excessive forces
(vibration, impact, drop, etc.) to the battery.
- Do not store or use the battery at high temperatures or expose to direct
sunlight.
Analog input/output
The analog input/output have been found to be compliant to the European
standards in the aforesaid manual and directive. However, for the very best
performance from what are in fact delicate measuring and controlled output
devices, Mitsubishi Electric would like to make the following points.
As analog devices are sensitive by nature, their use should be considered
carefully. For users of proprietary cables (integral with sensors or actuators),
these users should follow those manufacturers' installation requirements.
Mitsubishi Electric recommends that shielded cables be used. If NO other EMC
protection is provided, users may experience temporary loss or accuracy between
+10% / -10% in very heavy industrial areas.
However, Mitsubishi Electric suggests that adequate EMC precautions be
followed for the users complete control system.
- Sensitive analog cables should not be laid in the same trunking or cable
conduit as high voltage cabling. Where possible, users should run analog
cables separately.
- Good cable shielding should be used. When terminating the shield at Earth,
ensure that no earth loops are accidentally created.
- When reading analog values, EMC accuracy can be improved by averaging
the readings. This can be achieved either through functions on the analog
products or through a user's program in the FX
Series PLC main unit.
3GE
Incorporated Items
Check if the following product and items are included in the package.
Included Items
 Main units
Product
FX
3GE
-24M,
Dust proof protection sheet
FX
3GE
-40M
Manuals [English]
1 manual
1. Features and cautions on using FX
PLC
3GE
FX
PLC has an Ethernet communication function and analog input/output
3GE
function built into a base that is FX
PLC.
3G
This section describes below differences between FX
and FX
3G
3GE
on use.
For details, refer also to the FX
Series User's Manual - Hardware Edition.
3G
→ Refer to FX
Series User's Manual - Hardware Edition.
3G
1.1 Additional function from the FX
series
3G
• Ethernet communication function
The PLC has a Ethernet communication function (Equivalent to FX
ADP).
• Analog input/output function
The PLC has analog input 2 channels, analog output 1 channel (Equivalent to
FX
-3A-ADP). Specifications differ from FX
-3A-ADP in part. For details,
3U
3U
refer to Chapter 6.
1.2 Programming tool
GX Works2 Ver. 1.91V or later can be used. Select "FX3G" in "PLC Type". When
setting "Ethernet port settings", using GX Works2 Ver.1.91V or later.
FX-30P and GX Developer can also be used. However, "Ethernet port setting"
cannot be set.
In the case that the version does not support FX
3G
, the programming tool can still
be used by choosing FX
. However, programming is enabled only in the
1N
functional range such as instructions, device ranges and program sizes available
in a PLC selected as the alternative model.
1.3 Using the built-in Ethernet
When GX Works2 or MX Component is used, set the parameter settings and
connection destination settings of the built-in Ethernet using the same settings as
FX
3U
-ENET-ADP.
1.4 Terminal block
The input/output terminal block of FX
3GE
series PLC is built-in.
Terminal block cannot be removed.
STARTUP AND
MAINTENANCE
PRECAUTIONS
- Do not expose to water, bring near fire or touch liquid leakage or other contents
directly.
- When replacing the battery, make sure to use our specified product (FX
32BL).
- When a battery error occurs ("ALM" LED is lit in red), follow the description in
FX
Series User's Manual - Hardware Edition.
3G
- Incorrect handling of the battery may cause heat excessive generation,
bursting, ignition, liquid leakage or deformation, and lead to injury, fire or
failures and malfunctions of facilities and other equipment.
• Before modifying or disrupting the program in operation or running the PLC,
carefully read through this manual and the associated manuals and ensure the
safety of the operation.
An operation error may damage the machinery or cause accidents.
STARTUP AND
MAINTENANCE
PRECAUTIONS
• Turn off the power to the PLC before attaching or detaching the memory cassette.
If the memory cassette is attached or detached while the PLC's power is on, the
data in the memory may be destroyed, or the memory cassette may be damaged.
• Do not disassemble or modify the PLC.
Doing so may cause fire, equipment failures, or malfunctions.
For repair, contact your local Mitsubishi Electric representative.
• Turn off the power to the PLC before connecting or disconnecting any extension
cable.
Failure to do so may cause equipment failures or malfunctions.
• Turn off the power to the PLC before attaching or detaching the following devices.
Failure to do so may cause equipment failures or malfunctions.
- Peripheral devices, display module, and expansion boards
- Extension units/blocks and special adapters
- Battery and memory cassette
• For cleaning, perform dry wiping without using chemicals.
• If there is the possibility of touching the PLC inside a control panel in
maintenance,make sure to discharge to avoid the influence of static electricity.
DISPOSAL PRECAUTIONS
• Please contact a certified electronic waste disposal company for the
environmentally safe recycling and disposal of your device.
When disposing of batteries, separate them from other waste according to local
regulations.
(For details of the Battery Directive in EU countries, refer to FX
Manual - Hardware Edition.)
TRANSPORTATION AND
STORAGE PRECAUTIONS
• When transporting the FX
Series PLC incorporating the optional battery, turn
3GE
on the PLC before shipment, confirm that the battery mode is set using a
parameter and the ALM LED is OFF, and check the battery life.
If the PLC is transported with the ALM LED on or the battery exhausted, the
battery-backed data may be unstable during transportation.
• The PLC is a precision instrument. During transportation, avoid impacts larger
may also
than those specified in Section 3.1. Failure to do so may cause failures in the
PLC.
After transportation, verify the operations of the PLC.
• When transporting lithium batteries, follow required transportation regulations.
(For details of the regulated products, refer to FX
Hardware Edition.)
Overview
FX
PLC has an Ethernet communication function and analog input/output function
3GE
built into a base that is FX
PLC.
3G
The Ethernet communication function is equivalent to FX
The analog input/output function (analog input 2 channels, analog output 1 channel) is
equivalent to FX
-3A-ADP.
3U
Series
3G
Associated manuals
How to obtain manuals
For the necessary product manuals or documents, consult with your local Mitsubishi
Electric representative.
1.5 System configuration
- Special adapters can be directly connected to the main unit.
(It is not necessary to connect a connector conversion adapter.)
- One communication and one analog expansion option can be connected.
Expansion is available for one expansion board and two special adapters. But the
expansion board cannot be connected when two special adapters are connected.
- 40 point I/O type cannot use the BD1 slot.
- FX
3G
-CNV-ADP, FX
3U
-ENET-ADP cannot be connected.
- The communication channel of the built-in Ethernet is CH1. When a
communication expansion board or a communication special adapter is
connected to the PLC, that communication channel becomes CH2.
- The built-in analog is the analog special adapter first unit.
When an analog expansion board is connected, the analog expansion board
becomes second unit. When an analog special adapter is connected, the analog
special adapter becomes second unit.
Please refer to the following for details.
1) In the case of 40 point type
FX
Analog
Communication
FX
special adapter
special adapter
(Can be connected on top of other boards.)
Cannot use
BD1 slot
1 unit
1 sheet
FX
-232ADP (-MB)
3U
FX
-485ADP (-MB)
3U
One unit
and cautions
Maximum one unit
-ENET-
3U
FX
-4AD-ADP
FX
-4AD-PT-ADP
3U
3U
FX
3U
-4DA-ADP
FX
3U
-4AD-PTW-ADP
FX
-3A-ADP
FX
-4AD-PNK-ADP
3U
3U
FX
-4AD-TC-ADP
3U
One unit
Maximum one unit
Associated manuals
FX
3GE
Series PLC (main unit) comes with this document (hardware manual).
For a detailed explanation of the FX
for PLC programming and special function unit/block, refer to the relevant documents.
Specifications not described in this manual are same as FX
the following manual.
3U
-
→ Refer to FX
Manual name
FX
Series User's Manual
3G
- Hardware Edition
FX
/FX
/FX
/FX
/
3S
3G
3GC
3U
FX
Series
3UC
Programming Manual
- Basic & Applied Instruction
Edition
MELSEC-Q/L/F Structured
Programming Manual
(Fundamentals)
FXCPU Structured
Programming Manual
[Device & Common]
FXCPU Structured
Programming Manual
[Basic & Applied Instruction]
FXCPU Structured
Programming Manual
[Application Functions]
FX Series User's Manual
- Data Communication Edition
FX
3S
/FX
3G
/FX
3GC
/FX
3U
/
FX
Series User's Manual
3UC
- Analog Control Edition
FX
3S
/FX
3G
/FX
3GC
/FX
3U
/
FX
3UC
Series User's Manual
Series User's
3G
- Positioning Control Edition
FX
-ENET-ADP
3U
User's Manual
Certification of UL, cUL standards
Please consult with Mitsubishi Electric for information on UL, cUL standard practices
and the corresponding types of equipment.
Compliance with EC directive (CE Marking)
Series User's Manual -
3G
This product complies with EC directive, however, this document does not guarantee
that a mechanical system including this product will comply with the following
standards.
Compliance to EMC directive and LVD directive of the entire mechanical system should
be checked by the user/manufacturer. For more details please contact the local
Mitsubishi Electric sales site.
Requirement for Compliance with EMC directive
The following products have shown compliance through direct testing (of the identified
3U
-ENET-ADP.
standards below) and design analysis (through the creation of a technical construction
file) to the European Directive for Electromagnetic Compatibility (2014/30/EU) when
used as directed by the appropriate documentation.
Attention
This product is designed for use in industrial applications.
Type :
Programmable Controller (Open Type Equipment)
Models : MELSEC FX
3GE
from March 1st, 2013
from June 1st, 2013
from August 1st, 2013
2) In the case of 24 point type
Analog
Communication
special adapter
special adapter
3G
-EEPROM-32L
-5DM
3G
BD2
slot
FX
3U
-4AD-ADP
FX
-4DA-ADP
Expansion board
3U
FX
-3A-ADP
3U
[Communication]
One unit
FX
-232-BD
3G
FX
-485-BD
3G
FX
-485-BD-RJ
3G
FX
3G
-422-BD
[Input]
FX
-4EX-BD
3G
2. Outline
[Output]
FX
-2EYT-BD
3G
2.1 Part names
[Analog volume]
FX
-8AV-BD
3G
For the input/output extension units/blocks, refer to the following manual.
→ Refer to FX
[Analog input/output]
FX
-2AD-BD
3G
FX
-1DA-BD
3G
[16]
No.
[1]
Peripheral device connector cover
[2]
Terminal names
[3]
Top cover (S) (40points type only)
[4]
Top cover
[5]
Terminal block covers
[6]
Input display LEDs (red)
[7]
Extension device connector cover
Operation status display LEDs
POW
RUN
[8]
ERR
ALM
[9]
Output display LEDs (red)
[10]
Model name (abbreviation)
Series hardware and information on instructions
3GE
EN61131-2:2007
PLC. For details, refer to
3G
Series User's Manual - Hardware Edition.
3G
Manual No.
Description
Explains FX
Series PLC
3G
JY997D31301
specification details for I/O,
MODEL CODE:
wiring, installation, and
09R521
maintenance.
JY997D16601
Describes PLC programming for
MODEL CODE:
basic/applied instructions STL/
09R517
SFC programming and devices.
Requirement for Compliance with LVD directive
Programming methods,
The following products have shown compliance through direct testing (of the
SH-080782
specifications, functions, etc.
identified standards below) and design analysis (through the creation of a
MODEL CODE:
required to create structured
technical construction file) to the European Directive for Low Voltage (2014/35/
13JW06
programs.
EU) when used as directed by the appropriate documentation.
Type :
JY997D26001
Devices, parameters, etc.
MODEL CODE:
provided in structured projects of
Models : MELSEC FX
09R925
GX Works2.
from March 1st, 2013
from June 1st, 2013
JY997D34701
Sequence instructions provided
from August 1st, 2013
MODEL CODE:
in structured projects of GX
09R926
Works2.
For the products above,PLCs manufactured
JY997D34801
before February 28th, 2018 are compliant with EN61131-2:2007,
Application functions provided in
PLCs manufactured after March 1st, 2018 are compliant with EN61010-2-
MODEL CODE:
structured projects of GX Works2.
09R927
201:2013.
Explains N:N link, parallel link,
JY997D16901
computer link, no protocol
MODEL CODE:
EN61131-2:2007
communication by RS
09R715
instructions/FX
2N
-232IF.
Describes specifications for
JY997D16701
analog control and programming
MODEL CODE:
EN61010-2-201:2013
methods for FX
/FX
/FX
/
3S
3G
3GC
09R619
FX
3U
/FX
3UC
Series PLC.
Explains the specifications for
JY997D16801
positioning control of FX
/FX
/
3S
3G
MODEL CODE:
FX
/FX
/FX
Series and
3GC
3U
3UC
09R620
programming procedures
*1 For some models, PLCs manufactured after January 1st, 2018 are
JY997D45801
Describes FX
-ENET-ADP
3U
Caution for compliance with EC Directive
MODEL CODE:
Ethernet communication special
09R725
adapter details.
• Please use the FX
• Please secure the control box lid to the control box (for conduction).
• For the control panel, use the product having sufficient strength, fire
Caution for compliance with the LVD directive (EN61010-2-201:2013)
• To an external connection port other than AC power supply terminal and AC
• Between the commons having the adjacent relay output terminals, if an
• Do not wire two or more crimp terminals to one terminal. (If the wiring with two
• For crimp terminals to be used for the wiring applied with 30 V AC or higher,
• Cutoff device such as a breaker or a circuit protector should be installed in
series manufactured
FX
3GE
-MR/ES
FX
-MT/ES
FX
-MT/ESS
3GE
3GE
FX
-MR/DS
FX
-MT/DS
3GE
3GE
*2 For the time of compliance with the LVD directive (EN61010-2-201:2013),
FX
-MT/DSS
3GE
Where  indicates: 24, 40
No.
FX
-EEPROM-32L
3G
[11]
FX
-5DM
3G
(Can be connected on top of other boards.)
[12]
[13]
[14]
BD2
[15]
[16]
slot
With terminal cover open
Expansion board
[Communication]
FX
-232ADP (-MB)
3U
FX
-232-BD
3G
FX
-485ADP (-MB)
3U
FX
-485-BD
3G
FX
3G
-485-BD-RJ
One unit
FX
-422-BD
3G
[Input]
FX
3G
-4EX-BD
[Output]
FX
-2EYT-BD
3G
[Analog volume]
No.
FX
-8AV-BD
3G
[1]
Maximum one unit
[2]
[3]
FX
3U
-4AD-PT-ADP
[Analog input/output]
FX
-4AD-PTW-ADP
3U
FX
-2AD-BD
3G
FX
-4AD-PNK-ADP
3U
FX
3G
-1DA-BD
[4]
FX
-4AD-TC-ADP
3U
[5]
Maximum one unit
[6]
[7]
[8]
[9]
[10]
[11]
3G
Series User's Manual - Hardware Edition.
[12]
[12]
[1]
[2]
[3]
[4]
[5]
Right side
[6]
[7]
[8]
[9]
The authentication label for authorized products is affixed to the right side of the
[15]
[14]
[13]
[10]
[5]
product to avoid to be forged.
[11]
Products that do not have the genuine product certification label or nameplate are
not covered by the warranty.
Name
(80°C or more) for wiring.
2.2 LED status
PLC part
display
POW
RUN
Green
On while power is on the PLC.
Green
On while the PLC is running.
ERR
Red
Flashing when a program error occurs.
Red
Lit when a CPU error occurs.
Lit when the battery voltage drops.
Red
(When the optional battery is used)
Standard
Remark
Compliance with all relevant aspects of
Programmable controllers
the standard.
EMI
- Equipment requirements and
• Radiated Emission
tests
• Conducted Emission
EMS
• Radiated electromagnetic field
• Fast transient burst
• Electrostatic discharge
• High-energy surge
• Voltage drops and interruptions
• Conducted RF
• Power frequency magnetic field
Programmable Controller (Open Type Equipment)
series manufactured
3GE
FX
-MR/ES
3GE
FX
-MT/ES
FX
-MT/ESS
3GE
3GE
FX
3GE
-MR/DS
Where  indicates: 24, 40
*1
Standard
Remark
The equipment has been assessed
Programmable controllers
as a component for fitting in a
suitable control box which meets the
- Equipment requirements and tests
requirements of EN61131-2:2007
The equipment has been assessed
Safety of electrical equipment for
as a component for fitting in a
measurement,control,and test
suitable control box which meets the
requirements of EN61010-2-
201:2013
compliant.
3GE
Series programmable controllers while installed in
conductive shielded control boxes.
Installation within a control box greatly affects the safety of the system and aids
in shielding noise from the programmable controller.
protectiveness and shielding property to an installation environment.
input/output terminal, connect the circuit separated from a dangerous voltage
by a double/reinforced insulation.
external power supply is higher than 120 V AC, the insulation is basic.
Therefore, when using 120 V AC or higher external power supply and 30 V DC/
AC or lower external power supply between the adjacent commons, do not
handle 30 V DC/AC or lower external power supply as a touchable part, (When
handling 30 V DC/AC or lower external power supply as a touchable part, add
a basic insulation.)
or more wires is needed,take an appropriate action such as adding an external
terminal.)
use the products with insulating sleeves.
accordance with the following precautions.
- Use EN60947-1 or EN60947-3 standards.
- Place the cutoff device so that it can be operated easily.
- Specify that the cutoff device is for this equipment.
refer to FX3G Series User's Manual - Hardware Edition.
Name
DIN rail mounting hooks
Analog input terminal block
Analog output terminal block
10BASE-T/100BASE-TX connector (RJ45)
Ethernet status LEDs
Special adapter connector cover
[1] [2] [3]
[4]
[5]
[5]
[6] [7]
[12]
[5]
[11]
[10]
Name
Peripheral device connector (USB)
Peripheral device connector (RS-422)
RUN/STOP switch
Variable analog potentiometers
Upper side : VR1, Lower side : VR2
Terminal cover
Optional equipment connector
Power supply terminal, Input (X) terminals
Battery connector
Battery holder
Power supply terminal, Output (Y) terminals
Optional equipment connecting screw holes
Special adapter connector
Genuine product certification label
Nameplate
is a mark that instructs to use the cable with an appropriate temperature rating
LED
LED
Status
Description
color
ON
Power is on
Green
OFF
Power is off
ON
Running
Green
OFF
Stopped
ON
When a CPU error occurs.
Red
Flicker
When a program error occurs.
OFF
When a normal status.
When the battery voltage drops.
ON
(When the optional battery is installed.)
ALM
Red
When the battery voltage normal status.
OFF
(When the optional battery is installed.)
*2
[8]
[9]