Mercury U3V Cameras User's Manual
The acquisition time (unit: μs)
T
= (int (
acq
6)
For MER-133-54U3x camera:
In continuous mode, the row period (unit: μs)
In trigger mode, the row period (unit: μs)
The acquisition time (unit: μs)
7)
For MER-134-93U3x camera:
Row period (unit: μs)
The acquisition time (unit: μs)
When using a single ROI, the width and height represent the image width and image height of the
Region0, when using multi-ROI, the width and height represent the equivalent width and equivalent
height which are calculated by the Region0, Region1, Region2, and Region3. The specific calculate
method can see 2.2.2 section.
8)
For MER-230-168U3x camera:
When the pixel format is Mono8 or BayerRG8, the row period (unit: μs)
When the pixel format is Mono10 or BayerRG10, the row period (unit: μs)
The acquisition time (unit: μs)
9)
For MER-231-41U3x camera:
Row period (unit: μs)
The acquisition time (unit: μs)
10) For MER-301-125U3x camera:
When the pixel format is Mono8 or BayerRG8, the row period (unit: μs)
When the pixel format is Mono10 or BayerRG10, the row period (unit: μs)
The acquisition time (unit: μs)
11) For MER-302-56U3x camera:
996 − (height + offsety + 16)
8
offsety + 16
− ((int (
8
T
row
T
=
row
= ( ℎ + 30 ) ∗ Trow
T
acq
T
=
row
T
= ℎ ∗ Trow + 149.5
acq
T
row
T
row
T
= ( ℎ + 38 ) ∗ Trow
acq
T
row
T
= ( ℎ + 38 ) ∗ Trow
acq
T
row
T
row
T
= ( ℎ + 38 ) ∗ Trow
acq
offsety + 16
) + int (
8
) − 1) ∗ 8) + height + 1) ∗ T
1388
=
= 18.69
74.25
1650
= 22.222
74.25
Width
86 +
+ 10
2
72
180
=
= 4.8
37.5
360
=
= 9.6
37.5
746
=
≈ 19.89
37.5
190
=
= 5.07
37.5
380
=
= 10.13
37.5
) + (offsety + 16)
row
83