SPECIFICATIONS
Model
Power Supply
Pumping Capacity:
Discharge Head:
Tube Length:
Cable Length
Operating Temperature:
Thermal Protection:
Relay:
Pump Switching Levels:
Protection:
INSTALLATION
Location
This pump is not submersible. Select a suitable location for the pump within
the equipment which is level (fig. 4 & 5) and not likely to be disturbed in ge-
neral use. Ensure the drain hose slopes down directly to the pump without
drooping and kinking (fig. 3). If connecting directly to earthed / grounded
metal tray or pipes, allow 15mm (5/8") distance between parts (fig.12). Se-
HVAC/R
parate the pump and discharge tube from panels and surfaces with insula-
Service Products
ting foam rubber to further reduce noise transmission.
REFCO Manufacturing Ltd.
Industriestrasse 11
CH-6285 Hitzkirch (Switzerland)
ALARM LEVEL *1
PUMP ON
PUMP OFF
YUMA
230V 50Hz 30W
12 l/h
15 m (50ft) max
100 m (330ft) max
1 m / 3'4" - 0.75mm²
Air 50°C (122°F) max
Water 25°C (77°F) max
Auto-reset at 55°C (131°F)
5A 250V, Break on Alarm.
Pump On
17 mm (9/32")
Pump Off
12 mm (1/2")
Alarm Level *1
19 mm (3/4")
*1. Level must be above for 15 seconds to
trigger alarm.
IP20
Telefon +41 41 919 72 82
Telefax +41 41 919 72 83
Info@refco.ch www.refco.ch