Page 1
User' s Manual ( V2.7) Please read this manual carefully before the products are installed.Technical specifications and contents are subject to change accordingly without advance notification.
CONTENTS Page Part 1. Product introduction 1.1 Use purpose 1.2 System configuration 1.3 Features and functions Part 2. Technical parameters & structure 2.1 Technical parameters 2.2 Structure 6~12 Part 3. Installation and connection 3.1 Installation 3.2 Connection Part 4. System programming 13~15 4.1 Audio jumper 4.2 Video resistor...
Part 1. Product introduction 1.1 Use purpose The system is applied to single family houses, offices, shops, warehouses, and other access control purpose. 1.2 System configuration Configuration Options Remarks ① All panels are aluminum. ② There are options of the bracket (surface mount) and installation box Model No.
1.2.2 Indoor phones Model F-7 Model V-21 Model V-18 Model V-26 101X135X25(mm) 192X214X47(mm) 170X114X22(mm) 180X115X21(mm) Model V-16 Model V-17 Model V-25 Model N72B 210X150X23(mm) 266X184X23(mm) 266X184X23(mm) 225X157X26(mm) Model N75B Model V-22 Model V-23 Model N60 210X150X23(mm) 266X175X25(mm) 266X175X25(mm) 239X139X20(mm) 1.2.3 Power supply Adapter Transformer (DIN Rail)
Part 3. Installation and connection 3.1 Installation 3.1.1 Door stations Model No. 6 A) Surface mount Big seal a. Take off the coat from the door panel with Small seal expansion plugs the enclosed driver ( ). ① b. Install the expansion plugs in the wall beside the cable( ).
Page 9
expansion plugs Model No.15 A) Surface mount a. Take off the door panel from the bracket with the enclosed screw driver( ). ① b. Fix the bracket on the wall with two screws and expansion plugs( ). ② c. Put the door panel on the bracket and fix it ②...
C) Magnetic type a. Fix the bracket on the box or on the wall with the ③ screws( or ). ① ② b. Move the indoor ② phone and put it on ① the bracket after connect the cable( ). ③...
Page 11
3.2.2 Terminals Terminals to door station or/and indoor phone. Door station address code wires Both have no difference. Electronic lock selector(jumper) Audio jumper Terminal to power supply Program button Terminal for electronic POWER lock Terminal for electronic SIGNAL lock A) Door stations Lock1 Lock2 Lock2...
Page 12
Jp403 Jp402 +18V INPUT JP61(Loc k) AF- P Mod el N72B & N75B 3.2.3 Component diagram A. Basic connection e-lock B. Best connection for up to 4 door stations and 4 indoor phones RVV4x0.5mm e-lock RVV4x0.5mm RVV4x0.5mm e-lock RVV4x0.5mm RVV4x0.5mm e-lock RVV4x0.5mm RVV4x0.5mm...
Page 13
C2. Example 2: e-lock C3. Example 3: e-lock e-lock ①The basic components are 1 door station, 1 indoor phone, and 1 power supply. The max. capacity t he manufacturer suggests is 4 door stations and 4 indoor phones. More components may cause malfunctions. ②One adapter can support only one video indoor phone while one transformer can support up to 4 indoor phones.
Page 14
B) Diagrams for SIGNAL electronic locks B1. Indoor pho ne (exampl e: Model V-25) B2. Doo r station (exampl e: Model No. 15) JP402-IN JP403-OUT Lock1 AF- P +18V INPUT 12VDC Lock1 Lock2 Lock2 VIDEO 12VDC ①P ease choose one of the abovementioned diagrams according to the electronic locks. ②...
Part 4. System programming 4.1 Audio jumper The audio jumper has to be put on AF position in the indoor phone if there is only one indoor phone. In case there are more indoor phones, only the last indoor phone is required to do that. Meanwhile the other indoor phones' jumpers have to be put on NC position.
4.4 Card reader (for Model No.15 & No.18 only) A. Register master cards The system provides up to 8 master cards. Users may use the card to register or cancel other cards easily. ① a. Push the program button in the back side of the door station with a tool .Release it when the door station sounds a beep.
4.5 Password (for Model No.18 only) Residents are allowed to use passwords to release the doors on the door station Model No.18. A. Password settings a. Get into the program status Method 1>> Use the password on the door station. (Default password: 1234) For example, push *90*1234#.
Part 5. Operation 5.1 Operation on door stations 5.1.1 Call residents Push the CALL button on the door station. The door will sound a feedback ring if the calling is successful. The calling can be ended immediately once the call button is pushed again. If there is no answer, the calling will end itself after 15 seconds.
Page 19
5.2.3 Release gates/garages ... (Model N60 & N75B only) Push button if the indoor phones are with the function. 5.2.4 Video surveillance Push button and then the image in front of the camera will be displayed on the screen. If there are two or more cameras, surveillance for different entrances is also available by a 2nd, 3rd, or 4th push. During surveillance it is available to speak with somebody outside by pushing button and release the door by pushing button.
Page 20
5.2.9 Change the ring tone Keep pushing button for 2 seconds. The indoor phone will ring. Then continue to push the button again and again until the favorite ring sounds. 2" 5.2.10 Adjust the ring & speech volume Turn the wheel to decrease or increase the ring and speech volume. M - + All handsets are not available to adjust the ring and speech volume.
C. Cancel the recorded images During the reviewing status push button and do not release it for 2 seconds. The dialogue box will display. At this moment push button again, then the viewing page will be canceled. Then push “ ”...
Part 6. Troubleshooting 6.1 Test After all components are installed and connected as the user's manual, please switch the power on and then try to operate all features on all door stations and indoor phones as Part 5. 6.2 Troubleshooting Common malfunctions Possible reasons Obviation...