  • Page 1 Instruction  Manual                                       Model  1823A       2.4  GHz  Universal  Frequency  Counter GlobalTestSupply www. .com Find Quality Products Online at: sales@GlobalTestSupply.com...
  • Page 2   Introduction     Thank   you   for   purchasing   our   product.   Electronic   measuring   instruments   produced   by   us   are   high   technology   products   made   under   strict   quality   control.   We  guarantee  their  exceptional  precision  and  utmost  reliability.
  • Page 3: Table Of Contents

      CONTENTS     1.  PRODUCT  DESCRIPTION                   1-­1.  Introduction  -­-­-­-­-­-­-­-­-­-­-­-­-­-­-­-­-­-­-­-­-­-­-­-­-­-­-­-­-­-­-­-­-­-­-­-­-­-­-­-­-­-­-­-­-­-­-­-­-­-­-­-­-­-­   (  4  )                   1-­2.  Technical  Specifications  -­-­-­-­-­-­-­-­-­-­-­-­-­-­-­-­-­-­-­-­-­-­-­-­-­-­-­-­-­-­-­-­-­-­-­-­-­-­   (  5  )    ...
  • Page 4: Product  Description

      1.  PRODUCT  DESCRIPTION                       1-­1.  Introduction                       This  reciprocal  UNIVERSAL  COUNTER  series  are  microprocessor  controlled  ...
  • Page 5: 1-­2.  Technical  Specifications  -­-­-­-­-­-­-­-­-­-­-­-­-­-­-­-­-­-­-­-­-­-­-­-­-­-­-­-­-­-­-­-­-­-­-­-­-­-­   (  5  )

        1-­2.  Technical  Specifications     n   INPUT  A  CHARACTERISTICS   •  FREQUENCY  RANGE   :  0.1  Hz  to  100  MHz  (DC  Coupled)   30  Hz  to  100  MHz  (AC  Coupled)   •  SENSITIVITY     :  0.1   Hz   to   1   Hz:   250   mV    ...
  • Page 6         •  MAX.  INPUT  VOLTAGE  LEVEL                         100M   FREQUENCY  (Hz)     FIG  1.  MAX.  Input  Level.  (Input  A,B)     n   INPUT  B.  CHARACTERISTICS  =  Same  as  Input  A    ...
  • Page 7   n   INPUT  C.  CHARACTERISTICS     h  FREQUENCY  RANGE:  80  MHz  to  2.4  GHz   h  SENSITIVITY:   50  mV  from  80  MHz  to  150  MHz     50  mV  from  150  MHz  to  2.0  GHz    ...
  • Page 8: 1-­3.  Equipment  Ratings  -­-­-­-­-­-­-­-­-­-­-­-­-­-­-­-­-­-­-­-­-­-­-­-­-­-­-­-­-­-­-­-­-­-­-­-­-­-­-­-­-­-­-­-­-­   (  8  )

        :  Depending  on  input  frequency   •  GATE  TIME         <  10  mS-­-­-­-­-­-­-­-­-­-­-­-­Somewhere  between  0.9  and  9  mS           <  0.1  S-­-­-­-­-­-­-­-­-­-­-­-­-­-­Somewhere  between  9  and  90  mS        ...
  • Page 9: 1-­4.  Supplied  Accessories  -­-­-­-­-­-­-­-­-­-­-­-­-­-­-­-­-­-­-­-­-­-­-­-­-­-­-­-­-­-­-­-­-­-­-­-­-­-­-­-­-­-­   (  8  )

        2.  INSTALLATION                       2-­1.  Initial  Inspection       This  instrument  was  carefully  inspected  both  mechanically  and  electrically   before  shipment.
  • Page 10: Operation

                3.  OPERATION   3-­1.  Controls,  indicators  and  connectors                                 FIG(2)  FRONT  PANEL       GATE  INDICATOR       :  The  gate  light,  when  lit,  indicates  the  main  gate  is   open  and  measurement  in  progress.
  • Page 11       INPUT  C,  BNC              :  Input  for  frequency  measurements  above  80  MHz   Female  BNC  connector  terminated  in  50  Ω.     LOW  PASS  FILTER  :     With  this  switch  pushed  in,  the  input  B  is  routed   through  a  SWITCH(LPF)  low-­pass  filter  with  -­3  dB  ...
  • Page 12   displays  that  count.   f.  T.l  (A→B).  When  this  mode  is  selected,  the  unit         measures  the  time  interval  from  an  edge  of  the  input   A  signal  to  an  edge  of  the  input  B  signal.  Positive   going  or  Negative  going  edge  of  each  signal  is  ...
  • Page 13                     VOLTAGE   FUSE POWER  MAX   115V  ~ 0.5A  F 230V  ~ 0.2A  F S/N  :   Made  in  Korea           FIG  (3)  REAR  PANEL    ...
  • Page 14: 3-­2.  Operating  Instruction

        3-­2.  Operating  Instruction                       Below  is  the  basic  operating  information  needed  for  frequency  counter.     a.  Connect  the  unit  to  AC  power  cord  into  receptacle  on  rear  panel  and      ...
  • Page 15: 3-­4.  Period  Measurements

                            3-­3-­2   INPUT  C  (80  MHz  to  2.4  GHz)     CAUTION   THE  MAXIMUM  INPUT  LIMIT  TO  THIS  INPUT  IS  3  Vrms  MAXIMUM  OVER   THE  INPUT  FREQUENCY  RANGE.
  • Page 16: 3-­6.  Time  Interval  Measurement(A-­B)

        3-­6.  Time  Interval  Measurements(A → B)                         In  time  interval  mode,  unit  measures  the  elapsed  time  from  a  selected  edge  of   the  input  A  waveform  to  a  selected  edge  of  the  input  B  waveform.
  • Page 17: 3-­7.  Ratio  Measurement  (A/B)

        Frequency  Ratio  Measurements  (A/B)     3-­7.                         In  this  mode  of  operation,  the  counter  displays  the  ratio  of  the  frequency  applied   to  input  A  to  the  frequency  applied  to  input  B.
  • Page 18: 3-­8.  Use  Of  Rs-­232C  Serial  Interfacing

        3-­8.  Use  of  RS-­232C  Serial  Interfacing   1)  Hardware/Software  Requirements               .  IBM  PC/XT/AT  or  compatible  computer               .  Microsoft  Windows   .
  • Page 19: Maintenance

        4.  MAINTENANCE       CAUTION   IT  IS  ESSENTIAL  FOR  SAFETY  TO  PROPERLY  MAINTAIN  AND  SERVICE   THIS  INSTRUMENT     WARNING   VOLTAGES  WITHIN  THIS  INSTRUMENT  ARE  SUFFICIENTLY  HIGH  TO   ENDANGER  LIFE.  COVERS  MUST  NOT  BE  REMOVED  EXCEPT  BY   PERSONS  QUALIFIED  AND  AUTHORIZED  TO  DO  SO  AND  THESE  ...
  • Page 20: Others

      5.  OTHERS     5-­1.  BNC  Cable  Considerations                         Accuracy  of  radio  frequency  measurements  can  be  affected  by  connections   between  signal  source  and  counter.
  • Page 21: 5-­3.  Line  Frequency  Measurements

        5-­3.  Line  Frequency  Measurements                         Use  of  the  attenuator,  low  pass  filter,  and/or  x10  probe  is  advisable  when   measuring  line  frequency  because  the  high  amplitude  signal  and  noise  can  cause  ...