For The User - Daikin VAM350J7VEB Installer And User Reference Manual

Heat reclaim ventilation unit
Hide thumbs Also See for VAM350J7VEB:
Table of Contents

Advertisement

Q1DI
Field earth leak detector (≤300 mA)
R1T
Thermistor (indoor air)
R2T
Thermistor (outdoor air)
R3T
Thermistor (PTC)
S1C
Limit switch damper motor
V1R
Diode bridge
X1M
Terminal (A1P)
X2M
Terminal (outside input) (A1P)
X3M
Terminal (power supply)
Z1C
Noise filter (ferrite core)
Z1F
Noise filter
User interface
SS1
Selector switch
Connector for option
X14A
Connector (CO
X24A
Connector (outside damper)
X33A
Connector (contact PCB)
X35A
Connector (power supply adapter PCB)
For VAM350~650
C1
Capacitor (A2P)
F2U
Fuse (250 V, 5 A, T) (A2P)
F4U
Fuse (250 V, 6.3 A, T) (A2P)
K1R
Magnetic relay (A2P)
M1F
Motor (supply air fan)
M2F
Motor (exhaust air fan)
Z2C
Noise filter (ferrite core)
For VAM800+VAM1000
F3U
Fuse (250 V, 6.3 A, T) (A2P+A3P)

For the user

15
User interface
CAUTION
NEVER touch the internal parts of the controller.
Do NOT remove the front panel. Some parts inside are
dangerous to touch and appliance problems may happen.
For checking and adjusting the internal parts, contact your
dealer.
Detailed information on required actions to achieve certain functions
can be found in the dedicated installation and operation manual of
the indoor unit.
Refer to the operation manual of the installed user interface.
16
Before operation
WARNING
This unit contains electrical parts.
WARNING
Before operating the unit, be sure the installation has been
carried out correctly by an installer.
VAM350~2000J7VEB
Heat reclaim ventilation unit
4P487293-1 – 2017.08
sensor)
2
M1F
Motor (exhaust air fan)
M2F
Motor (supply air fan)
For VAM1500+VAM2000
F3U
Fuse (250 V, 6.3 A, T) (A2P~A5P)
K5R
Magnetic relay (A1P)
M2D
Motor (damper)
M1F
Motor (exhaust air fan) (bottom)
M2F
Motor (supply air fan) (bottom)
M3F
Motor (exhaust air fan) (top)
M4F
Motor (supply air fan) (top)
S2C
Limit switch damper motor
Symbols:
Field wiring
Terminals
Connectors
Protective earth
Noiseless earth
Colours:
BLK
Black
BLU
Blue
BRN
Brown
GRN
Green
ORG
Orange
RED
Red
WHT
White
YLW
Yellow
CAUTION
Do NOT operate the system when using a room
fumigation-type insecticide. Chemicals could collect in the
unit, and endanger the health of people who are
hypersensitive to chemicals.
Operation modes:
▪ Heat exchange mode.
▪ Bypass mode.
17
Energy saving and optimum
operation
Observe the following precautions to ensure the system operates
properly.
▪ Adjust the air outlet properly and avoid direct air flow to room
inhabitants.
▪ NEVER place objects near the air inlet or the air outlet of the unit.
Doing so may cause a reduced heating/cooling effect or stop
operation.
15 User interface
Installer and user reference guide
41