7 – What to do if ...
Some basic operations for the resolution of small problems which may arise during the use of Aqua Timer Plus are
described below.
If the suggestions shown do not help to resolve the situation, please call the SIATA service assistance.
7.1 - ... Aqua Timer Plus does not come on ?
1.
Check that the plug is correctly inserted in the electricity socket;
2.
Check that the socket is correctly supplied;
3.
Check that the current conductors are corrected inserted into the terminals and that these are closed correctly.
4.
Check that the fuse positioned on the panel has not blown.
In the case of Aqua Timer Plus at 230 Vac, AT-PLUS2/05, this fuse must be of delayed 0.5A;
7.2 - ... the motors of the distributors do not stop ?
1.
Check that the run end wires of the distributors, marked 96-S, are correctly inserted in the terminals and that these
are closed correctly;
7.3 - ... there is no current to the utilisers?
Remember that Aqua Timer Plus does not supply current to the outlets, but only closures that the operator must
1.
wire at his own discretion, check that the wiring is correct, that the conductors are correctly inserted into the
terminals and that these are closed correctly;
7.4 - ... Aqua Timer Plus works in an irregular way?
1.
Check that the distributors are at the stroke end, that is that the motors are not in movement;
2.
Check that the controller is correctly programmed;
3.
Key in the code 220 to initialise Aqua Timer Plus;