Advertisement

INSTRUCTION MANUAL
We thank you for purchasing our
product. Please read this owners
manual carefully before using the
Heater. It is important that you handle
and use the Unit according to the in-
structions to ensure its long life and
to avoid problems and accidents. Af-
ter reading this guide, keep it for fu-
ture reference.
DANGER
NO GASOLINE
L I Q UI D COMBUSTI B L E
ONL Y
INDEX
Pre-operation Instructions
Special precaution for safety.......................... 34
List of parts..................................................... 37
Preparation procedures.................................. 41
Unpacking.................................................. 41
Pre-ignition preparations and checkpoints. 41
Fuel to be used .......................................... 42
Fuel filling................................................... 44
Elevation adjustment.................................. 44
Operating Instructions
Ignition ........................................................... 45
Turning off...................................................... 46
Room temperature adjustment....................... 47
Time adjustment............................................. 48
Timer operation .............................................. 49
Child safety devices ....................................... 50
Maintenance and Others
Some cautions ............................................... 51
Maintenance .................................................. 52
Regular maintenance .................................... 54
Trouble-shooting ........................................... 55
Parts replacement/ Storage ........................... 58
Specifications................................................. 59
31

Advertisement

Table of Contents
loading

Summary of Contents for Tayosan SRE 3001

  • Page 1 INSTRUCTION MANUAL INDEX We thank you for purchasing our product. Please read this owners manual carefully before using the Pre-operation Instructions Heater. It is important that you handle Special precaution for safety......34 and use the Unit according to the in- List of parts.............
  • Page 2 SUMMARY OF THE SAFETY PRECAUTIONS IMPORTANT – DANGER – CAUTION · Be sure to shut off operation before you sleep or go out (p. 34) · Never use highly volatile fuels, such as gasoline, etc (p. 35) · Shut off operation when refuelling (p. 35) ·...
  • Page 3 SUMMARY OF THE OPERATION IGNITION – SHUTTING OFF – FASTEN IGNITION To ignite your heater, press the switch ON, the operation lamp lamp goes red. During ignition (+/- 2 minutes), a calculation will be done from 5 to 1 then the apparatus ignites. To shut off your heater, press the switch OFF, the operation lamp goes out, the blower fan will remain on for approximately 3 minutes to cool down your heater.
  • Page 4: Special Precaution For Safety

    SPECIAL PRECAUTIONS FOR SAFETY Special precautions are very important for you to use your fan heater. DANGER Extremely dangerous to cause high risk of death or fatal casualty. WARNING Very dangerous to cause high risk of death or serious casualty. CAUTION May cause high risk of serious casualty or other physical damage.
  • Page 5 CAUTION CHECK the fuel leak. Fasten the fuel tank cap AVOID locations close to drapes of flammable ma- securely. Hold the tank with top-side down to terial. make sure it is not leaking. DO NOT put laundries, sofas, too close to the Leaking fuel can easily catch fire.
  • Page 6 SPECIAL PRECAUTIONS FOR SAFETY CAUTION HANDLE WITH CARE the power cord. The power cord mustn't be given stressful force or nothing must be rested on it.  Also keep it away from heated blow wind. Do not hold and pull the cord when unplugging. ...
  • Page 7: List Of Parts

    LIST OF PARTS External Components *All cords are omitted to simplify the illustration. Fuel tank FRONT: Fuel gauge Fuel tank cover Tank handle Control panel Indicators *Upright position Fuel feeder cap Burner unit Gasket (black) I n s p e c t i o n window *Do not lose it.
  • Page 8 LIST OF PARTS Control Panel/ Indicators for SRE 3001 / FR 32 *All indicators are illustrated "lit" status for descriptions. ODOR-FREE LAMP TIMER CONTROL KEY (TIMER LAMP) The lamp is lit: Odor-free system For time setting, TIMER, the switch TIMER is light green: is activating at the timer operation is in stand-by status.
  • Page 9 LIST OF PARTS Control Panel/ Indicators for SRE 4600 / FR 46 *All indicators are illustrated "lit" status for descriptions. SWITCH/TIMER LAMP ODOR-FREE LAMP For time setting, timer on/off. The lamp is lit: Odor-free system The lamp is lit: timer operation is in stand-by status. is activating at the Ignition at the extinc- tion...
  • Page 10 DIGITAL INDICATORS Indicates pre-heating, errors, elevation, temperature, current time, and timer-programmed time. Pre-heating  Errors Indication on Fuel filling  Flash + Buzzer... Elevation lamp is lit  The unit buzzers and the filling  Elevation adjustment is done. sign lights 30 minutes and 5 minutes before the heater is Indications will change by pressing INDICATOR SELECTOR.
  • Page 11: Unpacking

    PREPARATION PROCEDURES Unpacking Remove a protection sheet on the top.  Open a fuel tank cover, remove the tank stopper to pull out  the tank. Remove all the adhesive tapes.  Keep the box for the later storage use. ...
  • Page 12 Fuel to be used More than 95 % of problems are due to using a wrong type of liquid combustible for mobile heater. Those problems are not covered by our guarantee. Only top-quality liquid combustible for mobile heater, with the aromatics removed and totally free of impurities (max 1 % of aromatics and a flash-point above 61°).
  • Page 13 What is liquid combustible for mobile heater of bad quality or unrefined ? * liquid combustible mobile heater liquid combustible for mobile heater of exposed to the sun or high humidity the last season. Season * liquid combustible for mobile heater mixed * liquid combustible for mobile heater stored with some water or dust or an other type in a container not well closed or the colour...
  • Page 14: Fuel Filling

    Upright two tank handles and hold them together as illus-  trated to pull up and remove the filler cap (for SRE 4600/FR 46) or unscrew the stopper (SRE 3001/FR 32). Fill the tank. Place the tank on a flat, even floor, and use a fuel feeder.
  • Page 15: Ignition

    IGNITION For SRE 3001 / FR 32 For SRE 4600 / FR 46 TIMING Ignition Press <ON> key. Operation lamp (same as <ON> key) will lit red. The lamp is red under any of the heat power modes. Preheating begins with "05" shown on the digital indicator.
  • Page 16: Turning Off

    TURNING OFF TURNING OFF Press <OFF> key. Flames go out, and "ON" lamp goes off.  Odor-free lamp lits during the cycle of extinction and then cuts off.  *Fan rotation may sound louder as the odor-free system is activated. *Digital indicators will indicate whatever the modes selected during operation.
  • Page 17: Room Temperature Adjustment

    ROOM TEMPERATURE ADJUSTMENT For SRE 3001 / FR 32 TIMING For SRE 4600 / FR 46 ROOM TEMPERATURE ADJUSTMENT The Unit is preset to bring room temperature to 20 centigrade. This is adjustable by pressing <TEMP. ADJUST SELECTOR> keys. The system will automatically adjust the heat power according to the programmed temperature.
  • Page 18: Time Adjustment

    Time Adjustment Time Adjustment Time adjustment is available both on- and off-operation status. Ex. To adjust to PM. 8:35 Press on switch MODE one or two times for the hour appear on the electronic display. The display indicate “-:- - “ Press the button - or + to select the hour Press the key once and digital display will indicate «0:00», then the current time.
  • Page 19: Timer Operation

    TIMER OPERATION For SRE 3001 / FR 32 TIMING For SRE 4600 / FR 46 TIMER OPERATION Timer operation is available only after the current time is entered. *When < TIMER CONTROL > key is pressed, buzzer sounds as the current time is displayed.
  • Page 20: Child Safety Devices

    CHILD SAFETY DEVICES CHILD SAFETY DEVICES Press <CHILD SAFETY> key for 3 seconds. "Child safety" is indicated with peep sound. Under <ON> operation: All functions except extinguishment [ off ] key are re- Timer Release stricted. Under <OFF> operation: Press <OFF> key. All functions except cancellation of child safety sys- Timer lamp goes off.
  • Page 21 SOME CAUTIONS AIR-SENSOR DETECTOR This heater has been designed with an Air-sensor device. Abnormal conditions of use of your heater (bad ventilation or too small a room) will automatically pro- voke the shut-off of your heater and the Air-sensor light will come on. IMPORTANT Any tampering with or modification to the safety system is prohibited.
  • Page 22: Maintenance

    MAINTENANCE WARNING! All cleaning and maintenance must be done after putting out flames, disconnecting the plug from outlet after the Unit is entirely cooled down. Do not disassemble safety devices, electromagnetic pumping unit, and other electrical compo- nents. After Each Use: Always check that there is no flammable object such ...
  • Page 23 WARNING! Remove dust or metallics, if any, on the space between blades. It may catch fire (known as "a tracking phenomenon"). At Least Once A Year: Shove the Unit while it is operating, to check that Auto Shut-off Device functions properly and flames go out. (Confirm that digital indicator displays "E4"...
  • Page 24: Regular Maintenance

    MAINTENANCE WARNING! When pumping fuel out of the tank, be sure to put out all flames, and unplug the Unit, other- wise it may cause imperfect combustion. Water Drain/Oil Drain of Fuel Receiver In such case that water is mixed into fuel, and that stops combustion, take the following steps to drain water.
  • Page 25: Trouble-Shooting

    TROUBLE-SHOOTING Guide The following phenomena may arise during normal operation. You should check the potential causes before consulting your local distributor. Description Cause & Solution Smoke and smell come out from Floor and wall covering and/or dust may be burning. the Unit Ventilate the room for about 10 ~ 15 minutes to let smoke and smell go out and bring your heater to...
  • Page 26 TROUBLE-SHOOTING Guide Error codes along with lamp lights indicates malfunctions. For SRE 3001 / FR 32 TIMING For SRE 4600 / FR 46 Error Codes/ Lamps Indications (Devices/systems triggered) <ON> key has been pressed for longer than 5 seconds. Ignition failure or state of flames is unstable.
  • Page 27 If recovery is unsuccessful or other error codes not listed below were shown, unplug the Unit once  and then place plug properly again, and press <ON> key. If recovery is still unsuccessful, contact your local distributor or the nearest customer service ...
  • Page 28 REPLACEMENT In case you need any parts replacement, contact your nearest customer service agent. *It is user's liability to use specified parts of our product. Any damage to the product or operational failure due to the false parts replacement is subject to the user's liability.
  • Page 29: Specifications

    SPECIFICATIONS SPECIFICATIONS MODELE SRE 3001 / FR 32 SRE 4600 / FR 46 Type Gasification at direct injection Ignition High voltage discharge ignition Fuel max Liquid combustible for mobile heater Fuel consumption (g/h) Average Fuel consumption 0.32 l/h 0.49 l/h...

This manual is also suitable for:

Sre 4600Fr 32Fr 46

Table of Contents