Sharp AR-5520 Service Manual page 40

A3 digital copier
Hide thumbs Also See for AR-5520:
Table of Contents

Advertisement

Main
Sub
Contents
code
code
43
13
Fusing paper interval control allow/
inhibit setting
44
01
Toner density control Enable/
Disable (ON/OFF) setting
16
Toner density control data check
and toner density control
correction amount display
Used to set the paper feed timing of 21st and later page to A3 or WLT when multi copying or printing
paper of narrow width. (A3 or WLT depends on the destination.)
When this simulation is executed, the currently set code number is displayed. Enter a desired code
number and press the [START] key, and the entered code number is written into the EEPROM and
the machine goes into the sub code entry standby mode.
Code number
0
1
<Applicable paper>
1) Paper tray: A4R, B5R, 8-1/2" X 14", 8-1/2" X 13", 8-1/2" X 11", A5, INV
2) Bypass tray: A4R, B5R, 8-1/2" X 14", 8-1/2" X 13", 8-1/2" X 11", A5, INV,16KR
*
A5 size for bypass tray is valid only for EX Japan AB series.
Setting is made whether the toner density control is performed or not.
When this simulation is executed, the current code number is displayed on the 7-seg display. (1=ON
[Enable], 0=OFF [Disable])
Enter a code number and press [START] key, and the setting is settled and saved into the EEPROM
and the machine goes into the sub code input standby mode.
Switching can be made with [AUTO/TEXT/PHOTO] key, and the set value of the selected mode is
displayed on the copy quantity display section.
The entered value at that time is written into the EEPROM.
LED
AUTO indicator
TEXT indicator
AUTO indicator & PHOTO indicator
TEXT indicator & PHOTO indicator
AUTO indicator & TEXT indicator & PHOTO indicator
<Descriptions on each correction>
Print ratio correction
In this correction, the toner supply interval is determined according to the print ratio, and an
overtoner is prevented.
Life correction
When the life of any consumable part approached the end, this correction prevents against
undertoner.
Note for items marked with
Drip infusion and Purge process are simulations for analysis, and do not set them to "Enable=1" in
the market.
If these items are set to "Enable=1", the toner density rises or falls extremely, resulting in developer
fall and toner dispersion.
If they are set to "Enable=1", developer must be replaced and the machine inside and the process
unit must be cleaned.
Unconditional toner supply
When the DV unit and the drum unit run idle, a small quantity of toner is consumed. To supply this
consumption, toner is supplied according to the rotation time of the DV unit.
The output value of the ATC sensor is checked and the toner density control correction value is
displayed on the 7-seg display.
The display mode can be switched by pressing [AUTO/TEXT/PHOTO] key.
When [Interrupt] key is pressed, the machine goes into the sub code input standby mode. When [CA]
key is pressed, the machine goes out of the simulation mode.
LED
AUTO indicator
The current output value of the ATC sensor is displayed.
TEXT indicator
The correction value according to the progress of life is added to the
current output value of the ATC sensor and the sum is displayed.
AR-5520 SIMULATIONS 7-13
Details of operation
Setting
Inhibit
Allow
Print ration correction
Life correction
Drip infusion
Purge process
Unconditional toner supply
Display content
* Default
Setting mode
Default
1
1
0
0
1

Hide quick links: