Accuracy - Omega OM-USB-2404-60 User Manual

4-channel voltage input ucb data acquisition module
Table of Contents

Advertisement

OM-USB-2404-60 User's Guide
Full performance requires connections to a USB 2.0 Hi-Speed host controller and USB 2.0 high-
Note 1:
speed hubs.) The maximum sample rate may be lower on USB 1.1 ports.

Accuracy

Measurement conditions
Calibrated maximum (–0 to 60 ºC)
Calibrated typical (25 ºC, ±5 ºC)
Uncalibrated, maximum
(–0 to 60 ºC)
Uncalibrated, typical
(25 ºC, ±5 ºC)
The range is equal to 62.64 V.
Note 2:
Power
Parameter
Current consumption from USB
Bus interface
Parameter
USB specification
Environmental
Parameter
Operating temperature range
Storage temperature range
Operating humidity
Storage humidity
Maximum altitude
Pollution degree (IEC60664)
Mechanical
Parameter
Dimensions
Weight
Table 2. Analog input accuracy
Percent of reading
(gain error)
±0.13%
±0.03%
±1.2%
±0.3%
Table 3. Power specifications
Specification
500 mA, maximum
Table 4. Bus specifications
Specification
USB 2.0 Hi-Speed mode (480 Mbps) is recommended.
Otherwise, USB 1.1 Full-Speed mode (12 Mbps)
Table 5. Environmental specifications
Specification
0 to 60 °C
–40 to 85 °C
10 to 90% relative humidity, non-condensing
5 to 95% relative humidity, non-condensing
2000 meters (6561.679 feet)
2
Table 6. Mechanical specifications
Specification
4.5" L x 5.5" W x 1.5" H
1.2 lbs. (544 grams)
13
Percent of range
(offset error) (Note 2)
±0.05%
±0.008%
±0.55%
±0.11%
Specifications