Troubleshooting Using the Fusion SingleStar Hub Status LEDs During
Table 8-9
Normal Operation
State
Action
Red
Use AdminBrowser to determine the
exact cause of the fault.
Power cycle one time. If the fault
remains, replace the Hub.
Use AdminBrowser to check if the
Hub is commanded Out-of-Service
(every Hub port
an RAU connected to the port, will
be red as well).
A power cycle will not clear a com-
manded Out-of-Service, you must
use AdminBrowser to clear this
state.
Alternating
Reduce input signal power; reduce
Red/Green
system gain.
Red
Replace the Hub.
Impact
Internal Hub fault.
Main Hub and all downstream units are
off-line.
LED, that has
RAU
Signal compression.
One or more power supplies are
out-of-specification.