Download Print this page

Philips FC9261 Service Manual page 2

Hide thumbs Also See for FC9261:

Advertisement

DISASSEMBLY- AND RE-ASSEMBLY ADVISE
- To open the appliance, first remove the filter cover
(item 39).
- Remove the can with the filters.
- Then remove the hingecover (2 screws A)
- When the hinge cover is removed, the dustcover can be
removed.
- Now remove the drive coupling (item 13) by turning it
clockwise.
- To remove the housing (9 screws F), for some screws you
will require a screwdriver with 14.5 cm long shrank.
Screwdriver 4322 009 08490 for T15 can be used.
- When the repair is finished, check whether all functions of
the appliance work properly.
- To disassemble the cord winder, use TORX screwdriver no.
T10, which is one of a set consisting of T20; T15; T10; T9;
T8; T7 and T6 (code number 4822 395 50145)
ELECTRICAL DIAGRAM
CORD
WINDER
RATTLE
DRIVE
MOTOR
M
IR PCB
IR
TRANSMITTER
Switch
Blue
Brown
Black
Red
Blue
REPAIR INSTRUCTION
- Due to precisely pre-adjusted belt-tension, rattle drive unit
(item 12) may only be replaced as a complete unit.
Do not disassemble this unit in any way!
- If the reel half spring unit is replaced, shaft (M) must be
lubricated with silicone grease. Do not apply any silicone
grease to or spill any grease on terminals (item 55) or
conductors (item 56).
- The cord winder spring must be tensioned to the maximum
level and the be rewound approx 1.5 turn.
- Item 15, air valve, opens to cool the motor if the air
displacement is too low or if the airflow is blocked.
Black
M
Black
FC9261
2-8

Advertisement

loading