STEP 2: INSTALL THE ODU MOUNTING BRACKET
A suitable mounting plate (8) must be procured or fabricated in
order to mount the supplied mounting bracket to a pole or mast.
The mounting bracket supplied maybe used as a template for holes.
Recommended mounting using mounting bracket
Note: Neoprene bonded stainless steel washers are included to
protect the anti-corrosion coating on the stand and to prevent
galvanic corrosion of the assembly. 316 stainless steel installation
hardware is recommended.
Installer supplies item 4, 6, 7 and 8
1. Take care when transporting the radome (1) and stand (2)
so as not to damage the corrosion resistant coatings.
2. Place an isolation gasket (3) onto the mounting post (8).
3. Place the stand (2) onto the isolation gasket, with the slotted
side facing down.
4. Slide a neoprene bonded isolation washer (5) onto an M10 hex
head bolt (4) , with its metal side contacting the bolt.
5. Slide this bolt assembly through the slot in the stand then through the hole
in the ship's mounting post.
6. Slide on another isolation washer with the rubber side facing the mounting post.
7. Thread on a jam nut (6) finger tight.
8. Thread on a hex nut (7).
9. Repeat steps 4-8 for the remaining three bolts.
10. Tighten the jam nuts using 10-12 ft-lbs of torque.
11. For all four bolts: preventing the jam nut and bolt from turning, tighten the hex nut against
the jam nut until they lock, taking care not to overtighten.
Note: Prior to connecting the ODU/IDU cable, the RJ-45 connector must be grounded using strap wire/electrical
clips to the vessel ground (not an existing electrical system ground). This is required to prevent static discharge
when connecting to the system.
NOTICE:
Install ground cables for both the ODU and IDU before using Pilot Land Station. Instructions on
how to install the ground cables are provided in the Installation Guide. Failure to properly ground the ODU
and the IDU could result in property damage in the case of a lightning strike or other excessive static
build-up.