AXS-100 Slave Controller
For AXS-100 and AXS100XT Access Control Systems
Introduction
The AXS-100 Slave Controller is a cost effective solution that
extends
AXS-100
or
AXS100XT
functionality up to 16 doors on a single RS-485 data loop using
any combination of up to *8 'Master' or 'Slave' controllers.
Each AXS-100 slave controller operates in real-time with
distributed intelligence and a full mirror database for offline
conditions. Should a communication failure occur between any of
the slaves and the master controller or between the master
controller and the host computer, each AXS-100 slave controller
will continue to function normally with no degradation in
performance and response times of card reading, alarm
activation or activation of logic events. Each AXS-100 slave can
also monitor the status of the protected doors (open or closed)
and the status of the door locks (locked or unlocked).
Initial system configuration is programmed via the master
controller's keypad. Functionality such as event log access, card
holder programming and/or mode updates are handled via EIRIS
V4.6 (or higher) or AXSalert enterprise software.
*One 'Master controller' is required for each RS-485 data loop.
CAUTION:
It is important that you read, understand, and
follow the instructions in this document. If you have
questions, call your local VT support representative.
1. Mounting and Initial Assembly
A.
Metal Box Mounting
The AXS-100 Slave Controller must be installed indoors, within
the protected premise, in accordance with the National Electrical
Code (NFPA70) and the local authorities having jurisdiction.
Note: Do not connect (the transformer) to a power receptacle that
is controlled by a switch.
B. Backup Battery Installation (Optional)
Locate the optional backup battery (12V, 7.0Ah, Lead-acid
battery) in the lower left side of the system enclosure (see fig. 2).
Page 1 of 6
DE62821A_V7.0
access
control
system
Backup
battery
(optional)
Installation Guide
Fig. 2 - Backup Battery

Advertisement

loading

Summary of Contents for VisAccess AXS-100

  • Page 1 AXS-100 Slave Controller For AXS-100 and AXS100XT Access Control Systems Installation Guide Introduction The AXS-100 Slave Controller is a cost effective solution that extends AXS-100 AXS100XT access control system functionality up to 16 doors on a single RS-485 data loop using any combination of up to *8 ‘Master’...
  • Page 2 C. Metal Box Door Lock Assembly D. Tamper Switch Installation & Wiring It is necessary to protect the controller against tampering. A UL The door lock assembly of the system metal box is presented in Listed Tamper switch must be installed (see fig. 4) and wired to figure 3 (the lock and the brass nut are supplied in the system AUXIN1 and COM of lock #3 of each controller.
  • Page 3 Each reader is connected to the controller via a 4-wire cable. operation. The standard cable is color coded as follows: B. Inputs Power + • Each AXS-100 Slave Controller can be connected to two inputs BLACK Power – • per door as described below: GREENTX •...
  • Page 4 The AXS-100 Slave Controller can be connected to two electric Periodic Check locks as described below: Once a month, the AXS-100 Slave Controller must be checked by Each slave controller can operate both electromagnetic strikes - presenting a tag/card to the reader and verifying that the proper...
  • Page 5 5. Controller Configuration An AXS-100 Master-Slave system can control up to 16 doors on a single RS-485 data loop using any combination of up to 8 master or slave controllers. NOTE: One master controller is required for each RS-485 data loop.
  • Page 6 VT shall not, under any circumstances whatsoever, be liable for any 6. Standards Compliance inaccuracy, error of judgment, default, or negligence of VT, its This device complies with the essential requirements and employees, officers, agents, or any other party, or of the purchaser or provisions of Directive 1999/5/EC of the European Parliament user, arising from any assistance or communication of any kind and of the Council of 9 March 1999 on radio and...

This manual is also suitable for:

Axs-100st