Page 1
Specification Part numbers 1. Description and Operation The EBMPIR series of miniature PIR (passive infrared) presence detectors provide automatic control of lighting loads with optional manual control. The miniature size together with multiple mounting options make these products ideally suited for mounting in, or attached to, luminaires to provide local con- trol of individual fittings.
EBMPIR-DD & EBMPIR-AD single switch: short press turn on, short press turn off, press and hold cycles dimming. EBMPIR-DD & EBMPIR-AD two way switch: up button short press turns on, press and hold to dims up. Down button short press turns off, press and hold dims down.
Page 3
Side mounting bracket Flush holder page 3...
2. Dimensions cont. Power supply 3. Fixing The product is designed to be mounted directly to a luminaire, either on the inside or outside. the PIR lens must have a view outside the luminaire. versions with a lux sensor—for optimum operation the lens must shielded as much as possible from the light source.
Page 5
32mm Flush mounting Side mounting page 5...
Option B, a centre biased momentary switch gives the benefit of having separate switches to dim up and down—set switch mode 2 position switch together in this case. EBMPIR-B EBMPIR-PRM Non-dimming EBMPIR-DD EBMPIR-AD Dimming Switch Option A EBMPIR-DD EBMPIR-AD Dimming Switch Option B page 6...
(see section 6). The factory default is 20 minutes. EBMPIR-B—feature not available EBMPIR-PRM—switch level on lux setting determines the ambient light level at which the lights turn on. This can be set using the push button adjustment overleaf or the programming handset (see section 6).
Page 8
= 15 min.; 5 flashes = 20 min.; 6 flashes = 25 min.; 7 flashes = 30 min. Lux settings EBMPIR-PRM—1 flash turns on when very dark ; 7 flashes turns on regardless of ambient light. EBMPIR-DD & EBMPIR-AD—1 flash gives dim output level; 7 flashes gives maximum illumi- nance.
2.2.4 1 position switch separate Switching Channel 1 functions (factory default in brackets): (EBMPIR-DD & EBMPIR-AD—this channel controls the relay output, whereas Channel 2 controls the dimmed output. The parameters below should be programmed as well as the corresponding parameter on Channel 2) 3.1 Presence detection...
Page 10
Dimming Channel 2 functions EBMPIR-DD & -AD only (factory default in brackets): Light level Maintained illuminance level (adjustable between 1 and 999). At 999 the output will be always be at maximum. Presence detection Auto switch on with detection, auto off after movement ceases and (default) time delay ends.
7. Detection Patterns 8. Fault Finding LOAD DOES NOT COME ON LIGHTS DO NOT GO OFF Ensure that the area is left unoccupied for longer Check to see if the live supply to the circuit is good. than the selected timer setting. Strap across the L and LIVE OUT terminal to turn the load on.
+ 44 (0) 333 900 0674 www.cpelectronics.co.uk enquiry@cpelectronics.co.uk FM 45789 EMS 534520 Due to our policy of continual product improvement CP Electronics reserves the right to alter the specification of this product without prior notice. Ref #WD249 Issue 11 page 12...
Need help?
Do you have a question about the EBMPIR and is the answer not in the manual?
Questions and answers