Figure 27: Finishing tuning and download parameter settings to the Drive
Err_check
Error Check: This window shows both the present status of each error event and their history.
Current error event(s) can be reset by clicking Erase Current Err! button, and all error events
can be reset by clicking Erase All! button. List of the last ten drive faults. #0 being the most
recent, #9 is the oldest. See Figure 28.
Figure 28: Error check window
OverCurrent: Over-current Protection. Protection will be activated when continuous current
Tel: +000 0000-00000000
DM422C Digital Stepping Driver Manual V1.0
27
info@dold-mechatronik.de
www.dold-mechatronik.de
exceeds 16A.
OverVoltage: Over-voltage Protection. When power supply voltage exceeds 42±1 VDC, protection
will be activated.
PhaseErr: Phase Error Protection. Motor power lines wrong & not connected will activate this
protection.
ErrCounter: Displays current error(s) and current error history.
Erase Current Err!: Erase Current Err button. The user can clear current error(s) by clicking this
button.
Erase All!: Erase All! button. The user can clear all error(s) including error history by clicking this
button.
About
The user can choose two drop-down menus by clicking "About", including Product Information and
Contact Us.
Product Information window: Shows some product information about ProTuner.
Contact Us window: Shows some contact information about Leadshine.
Figure 29: Product information
Figure 30: Contact information
Tel: +000 0000-00000000
DM422C Digital Stepping Driver Manual V1.0
28
DOLD Mechatronik
Sarach 10 – D-77790 Steinach
Telefon: +49 7832 / 9744670