Trouble Shooting And Fault Finding - Kedr MIG 160GDM User Manual

Table of Contents

Advertisement

6 Trouble shooting and fault finding

Notes: The following operations must be performed by qualified electricians with valid
certifications. Before maintenance, you are suggested to contact local distributor to
verify qualification.
Malfunctions
The meter shows nothing;
Fan does not rotate;
No welding output
The meter shows;
Fan works normally;
No welding output
The meter shows;
Fan works normally;
Abnormal indicator lights.
Confirm the power switch is on.
Power supply available for input cable.
Check if the silicon bridge is damaged.
There is malfunction occurs in the supplementary power
source on control board (contact dealers).
Check if all the sockets in the machine are connected well.
There is open circuit or badness of connect at the joint of
output terminal.
The control cable on the torch is broken off or the switch is
damaged.
The control circuit is damaged.(contact to dealers)
It might be over-current protection, please turn off the
power switch; restart the machine after the abnormal
indicator light winked.
It might be overheating protection, please wait for about 2-
3 minutes until the machine renew without turn off the
power switch.
It might be multifunction of inverter circuit. (contact
dealers)
Solution
21

Advertisement

Table of Contents
loading

This manual is also suitable for:

Mig 180gdm