OUTDOOR UNIT
MODEL RAC-25FXB, RAC-35FXB
1. Electrical parts
(1)Remove the upper cover fixing screws and lift
the cover to remove it.
(2)Remove the service valve cover.
(3)Remove the terminal plate cover.
(4)Remove the right side cover.
(5)Remove the electrical box fixing screws and
GND wire fixing screw.
(6)Remove P lock which binds lead wires.
(7)Set the electrical box upside down.
(8)Remove P.W.B. fixing screws (2 locations) and
radiation fin fixing screws (5 locations), and
remove the P.W.B. from the support.
10ー6
Radiation fin fixing screw
P.W.B. fixing screw