Technical Specifications

Advanced Battery Management (ABM™) Technology Doubles Battery Service Life
The lead-acid batteries typically used in a
UPS are considered viable as long as they
can maintain backup times of at least half
that of new batteries. The illustration to the
right shows that batteries that are constantly
trickle charged (as are virtually all other UPS
batteries on the market today) reach the end
of their useful life in less than half the time
of batteries charged using ABM. ABM uses a
patented three-stage charging technique that
not only doubles battery service life, but
also optimizes battery recharge time and
provides up to a 60-day advanced notifi-
cation of pending end of useful battery life.
E
I
L E C T R I C A L
N P U T
Voltage
120 and 230 Vac nominal; see Model Selection Guide for
user-selectable voltages
Online
-30%, +20% for nominal voltages; user-selectable
Voltage Range
extended range of -35%, +20%
Nominal Input
50/60 Hz; auto-selection
Frequency
Connections
See Model Selection Guide
E
O
L E C T R I C A L
U T P U T
Power Levels
450, 700, 1000, and 1500 VA
Online Efficiency
96%
Online Regulation
-10%, +6%; within Computer Business Equipment
Manufacturers Association's Guidelines (-15%, +10%
using extended range)
On Battery
±5% RMS
Regulation
Voltage Wave Shape Quasi-sine wave
(on battery)
No Load Sleep Mode Outputs are turned off if <5% load is detected (selectable)
Connections
See Model Selection Guide
Interconnecting
2 ea. IEC-320 (10 A); 230 Vac models only
Cords(cabinet)
Interconnecting
4 ea. IEC-320 (10 A)
Cords(rack)
Backup Time
See Battery Run Times table
Battery Charging
<4 hrs to 90% usable capacity
Battery Type
Sealed, maintenance-free lead-acid
Start-On-Battery
Startup with UPS batteries in absence of utility power
I
C
N D I C AT O R S A N D
O N T R O L S
Serial
Intelligent serial communication to provide alarms
Communication
with history, measured parameters, selftest, and many
other features.
Front Panel
Ergonomic indicators including wiring fault, battery
Interface LEDs
service, communication operation, system normal; bar
graphs for input level, battery charge level, % load
Digital Input/Output Remote On/Off
1
Data based upon tests performed by an independent battery manufacturer
P
H Y S I C A L
Dimensions and
See Model Selection Guide
Weight
Surge Suppression
High energy 6500 peak Amp
Audible Noise
Less than 45 dB
Operating Temp
0°C–40°C (32°F–104°F)
UL tested at 25°C (77°F)
Operating Humidity
5 to 95% non-condensing
Operating Altitude
Up to 10,000 feet above sea level
Conformance
IEEE 446, NEMA PE 1;
Standards
ANSI C62.41; FCC Class A and B, EN50091-2
Class B, NSTA and others
Safety Standards
UL 1778, CSA C22.2, and European standard
EN 50091-1
Network Transient
In and out RJ11 jack for telephone/modem
Protector
protection (120 Vac models only) or RJ45 for
10Base-T network cable; UL497A tested
P
P
O W E R
R O T E C T I O N
Series 5
Protection against power failures, power surges,
Protection
power sags, brownouts, line noise, and a degree of
protection against other power problems
1. Due to continuing product improvement programs, specifications are
subject to change without notice.
Input Voltage
Level
Site Wiring Fault
ABM (up to
60-day notice
for battery
service)
On Button
(Start-on-battery)

Front Panel Display

Battery Level
Load Level
C o m m u n i c a t i o n s
Off/Standby
Button
Alarm Silence/
Self-test Button

Advertisement