Code - Easy CDV43 User Manual

2-wire video intercom system
Table of Contents

Advertisement

7
11.4 How to set the slave monitor address
Maximum of 4 monitors can be connected in one apartment, one master monitor together
with 3 slave monitors, addresses must be the same.(note: must have one monitor to be
set as master monitor)
Code 8000 is used to set the master monitor.
Code 8001 is used to set the first slave monitor .
Code 8002 is used to set the second slave monitor .
Code 8003 is used to set the third slave monitor .
11.5 How to set the monitor panel on
In default mode, when receive a call, the master and slave monitors will ring at the same
time, only the master monitor will display the image while the slave monitors do not. The
settings can be changed, the system can be set to allow the master monitor and all the
slave monitors to display video at the same time when receiving a call, input the code
number of 8006 on each slave monitor.

cei 



11.6 How to set the unlock parameter
Unlock mode:
There are two unlock modes: 1. Power-on- to-unlock type: unlock mode=0(by default)
2. Power-off-to-unlock type: unlock mode=1.
The code number of 8010 is used to set the unlock mode to 0
The code number of 8011 is used to set the unlock mode to 1
Unlock time:
The unlock time can be changed at any time. It can be set from 1 to 9 seconds. Code
numbers from 8021 to 8029 are used to set the unlock time to 1~ 9 seconds.