  • Page 7: General Safety Instructions

    Instruction manual Dear customer! An emergency release is required for garages without a second Congratulations on the purchase of this product. access. A function test of the emergency release has to be carried This garage door operator has been developed according to state-of- out monthly! the-art technology and manufactured using the most reliable and high quality electrical / electronic components.
  • Page 8: Opener Assembly

    Opener assembly 12. Remove the light cover ATTENTION Loosen the screw from the light cover and remove the light cover. IMPORTANT INSTRUCTIONS FOR A SAFE 13. Mount the drive head to the rail MOUNTING Attach the motor shaft of the drive head to the pinion in the rail. ATTENTION –...
  • Page 9 Set - up Before start-up of the garage door opener it is necessary to release the trolley and open and close the door completely by hand. The trolley may not touch the motor head when the door is open and it may not touch the idler unit when the door is closed. S 201 01-07...
  • Page 10 Setting of force and path Hint: At first set-up of the opener (or after re-setting to the preset values) the opener switches automatically into the programming mode. If accidentally the end position got overstepped during the programming mode you have got the possibility to reverse the path direction by carrying out the following steps Press button S and keep pressed Press button L additionally...
  • Page 11 Adjustment of the single functions HINT: During the programming mode LED red and yellow are blinking rotationally and indicate the chosen menu point (numbers of blinking signals red LED) and the adjusted status (numbers of blinking signal of yellow LED). S 201 01-07...
  • Page 12 Re-setting to preset values (path and force as well) - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - (only for radio system PICO 868,5 MHz, if you install a different radio system Programming of the transmitter please follow the instructions of the radio system manual).
  • Page 13 Readjustment of the force via the digital potentiometer With the help of the digital potentiometer (preset value: middle position) the force at the door border can be adjusted to a untill certain degree. Press button of the digital potentiometer for 2-3sec all Poti-LEDs light up.
  • Page 14 SAFETY CHECK Maintenance We recommend double check of the complete plant (door + Before termination of the start up you need to opener) by a professional once a year. Force cut-off, con- do a safety check to see if the opener stops nected safety devices and function of the mechanical and reverses correctly according to the EU emergency lock need to be checked every 4 weeks.
  • Page 15 Error analysis Radio system PICO, 868,5 MHz 2 channel Lighting: • Light bulb defect: Transmitting Replace by a 24V/15W (E14) light bulb direction • Opener does not have power supply: Check mains supply lines and fuses and replace if necessary Radio system: •...
  • Page 16 Conformity S 201 01-07...