Summary of Contents for Optoelectronics OPL-2724

  • Page 1 Master Specification Wireless Barcode Scanner Product Name OPL-2724 Specification No. SS08057 Edition Initial Date of Publication Original Spec. No. SS08045 Optoelectronics Co., Ltd. 4-12-17 Tsukagoshi Warabi-shi, Saitama 335-0002 Japan TEL: +81 (0)48-446-1183 FAX: +81 (0)48-446-1184...
  • Page 2: Revision History

    Revision History Specification Number: SS08057 Product Name: OPL-2724 Revision Date Section Description of Changes Initial 2008/...
  • Page 3: Table Of Contents

    OPL-2724 SS08057 Table of Contents 1. Abstract..............................1 2. Overview..............................1 3. Physical Features ..........................1 4. Detailed View............................2 5. Basic Specifications ..........................3 6. Electrical Specifications ......................... 4 7. Technical Specifications......................... 4 8. Interface Specifications........................10 9. Operation Specifications ........................11 10.
  • Page 4: Abstract

    - Scanned data is transferred to the designated device via wireless communication (Bluetooth V2.0). - If the OPL-2724 is disconnected because it is out of range or the Bluetooth device is not available, scanned data will be saved in the built-in memory of the scanner.
  • Page 5: Detailed View

    OPL-2724 SS08057 4. Detailed View Figure 2: Detailed View Name Function 1. Trigger Switch To scan barcodes and to enable or disable Bluetooth communication. To notify the status of barcode scanning, Bluetooth communication, 2. 3-color LED (Red, Green, Blue) and warnings so on.
  • Page 6: Basic Specifications

    OPL-2724 SS08057 5. Basic Specifications Item Specifications Notes Control 16-bit CISC CPU section Clock frequency 14.74 M Hz External FROM 256 KB For BIOS/AP memory SRAM 32 KB For WORK/DATA Display 3-color LED (red, green, blue) section Function Notifies status...
  • Page 7: Electrical Specifications

    40° 0.45 or higher (Note*) (over 70% of reflectivity of space and quiet zones.) Barcode sample OPTOELECTRONICS test sample (9-digit Code-39) Resolution: 0.25 mm Distance 90 mm from the optical window Angle α = 0°, β = 15°, γ = 0°...
  • Page 8 The scan area is a circular area centered on the beam, which appears at various resolutions. Conditions: Resolution Symbology No of Digit Barcode Sample 1.0 mm Code-39 OPTOELECTRONICS test sample, PCS = 0.9 0.5 mm Code-39 OPTOELECTRONICS test sample, PCS = 0.9 0.25 mm Code-39 OPTOELECTRONICS test sample, PCS = 0.9 0.15 mm Code-39 OPTOELECTRONICS test sample, PCS = 0.9...
  • Page 9 OPL-2724 SS08057 7-2. Pitch Angle Pitch angle: α = ± 25° Figure 4: Pitch angle 7-3. Skew Angle Skew angle: β = ± 50° (excluding dead zone)
  • Page 10 OPL-2724 SS08057 7-4. Dead Zone Dead zone: β = ± 8° (There are some areas in which scanning may fail due to specular reflection.) Figure 5: Skew angle and dead zone...
  • Page 11 OPL-2724 SS08057 7-5. Tilt Angle γ = ± 20° <Conditions> Barcode Sample: OPTOELECTRONICS test sample PCS: Resolution: 0.26 mm Symbologies: 13-digit JAN (96 mm from the optical window of the scanner.) Figure 6: Tilt angle 7-6. Curvature With 8-digit JAN barcodes, decoding performance is guaranteed when R≧15mm.
  • Page 12 OPL-2724 SS08057 7-7. Scan Width Scannable barcode width differs depending on the depth of field. 7-8. Ambient Light Immunity Scanning performance is guaranteed when the range of illumination on a barcode surface is between zero and the following values: Incandescent Light: to 3,000 lx.
  • Page 13: Interface Specifications

    GAP (Generic Access Profile) SPP (Serial Port Profile) -Communication configuration 1 OPL-2724 to 1 Host System (Do not connect multiple scanners to one host system.) -Operation mode of the scanner while connected to the host system Master / Slave mode -Security mode Authentication enabled: These settings can be configured using menu barcodes.
  • Page 14: Operation Specifications

    OPL-2724 SS08057 9. Operation Specifications 9-1. Buzzer and LED Display OPL-2724 notifies its operation state with LED and buzzer on its head section. Overview Status Color Light Details of the Status Buzzer Shows that scanning of the barcode or transmission of scanned...
  • Page 15: Default Settings

    SS08057 10. Default Settings To make it easier to configure the settings of OPL-2724 to the default settings, there are [U1] menu barcodes. For communication settings, there are [INIT] menu barcodes. At the time of shipment from the factory, all settings are configured to [U1]. ([INIT] menu barcodes are included in [U1] menu barcodes.
  • Page 16 OPL-2724 SS08057 [U1] Default Settings 2: Read, trigger and buzzer options Item Default setting Setting the number of characters Fixed length OFF all codes Read mode Single read Multiple read reset time 500 msec Add-on wait mode 500 msec Redundancy...
  • Page 17: Durability

    OPL-2724 SS08057 11. Durability 11-1. Water Resistant and Dust-proof Features Item Specifications Water Resistant IP-X2 11-2. Anti-static Electricity Features Item Specifications Notes Air discharge: ±10 kV No malfunction Anti-static Air discharge: ±15 kV No destruction Electricity Indirect discharge: ±19 kV...
  • Page 18: Regulatory Compliance

    • EN300 328 • EN301 489 14-4. Others • Radio Law 38-24-1 • Bluetooth logo certifica tion 15. RoHS OPL-2724 is a RoHS compliant product. *RoHS: The restriction of the use of certain hazardous substances in electrical and electronic equipment,2002/95/EC.
  • Page 19: Display Of Product Information

    OPL-2724 SS08057 16. Display of Product Information Attach serial label, laser caution label and model name label as shown below: Manufacturer_ID_Label OPL27247039-0-01 LR03 LR03 CLASS 1 LASER PRODUCT IEC60825-1+A2:2001 Model_Name_Label Laser_Caution_Label OPL27247100-0-02 OPL27247032-0-00 Figure 9: Product Information...
  • Page 20 OPL-2724 SS08057 16-1. Individual Packaging Box Label Attach a label with the information listed below to the individual packaging box. OPL―2724 Model name *OF2OPL2724* Specification No. OPL2724 Item No. Serisla No. (6 digits) * 1 2 3 4 5 6...
  • Page 21: Packaging Specifications

    OPL-2724 SS08057 17. Packaging Specifications 17-1. Individual Packaging Specifications Put the OPL-2724 into a protective bubble bag and put it into the individual packaging box. Accessories: • Size AAA alkali batteries X 2 • Hand strap...
  • Page 22 RoHS standards (the restriction of the use of certain hazardous substances in electrical and electronic equipment, 2002/95/EC). This is an internal determination by Optoelectronics and carries no legal weight in the EU.
  • Page 23: Product Specification Changes

    12 (twelve) months beginning on the last day of the month in which it is shipped. Optoelectronics will repair product defects or malfunctions that arise in the course of normal usage during the twelve-month warranty period free of charge.
  • Page 24: Precautions

    • Do not stare into the beam with optical instruments. It may harm your eyes. 20-2. For the Radio Equipment OPL-2724, a radio equipment for low power radio station of 2.4 GHz band advanced data communication system specified in the Radio Law, has obtained the Certification for Construction Design of Specified Radio Equipment.
  • Page 25: Bluetooth

    It may effect the communication speed or communication range of this scanner. • The use of OPL-2724 outside of the European Union, the United States and Canada is punishable under the law. • Communication speed and communication range of OPL-2724 may differ due to the obstcles and radio wave conditions between OPL-2724 and the divice, which OPL-2724 is connected to.
  • Page 26 FCC Statement This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications.