Troubleshooting Procedures; Refrigerator Will Not Ignite Electrically On Propane - Norcold 442 Repair Manual

Hide thumbs Also See for 442:
Table of Contents

Advertisement

B101
Refrigerator Will Not
Ignite Electrically on
Propane
1. Check for 12 Volts DC be-
tween positive and negative
leads at the rear of the refrig-
erator. If not present, correct
source.
2. If 12 Volts DC is present, then
check the 3 Amp fuse for con-
tinuity. If open, then replace with
fuse of same size and rating.
WARNING
NEVER OVERFUSE A CIRCUIT.
REPLACE A BLOWN FUSE WITH
EXACT REPLACEMENT INDICATED
BY NORCOLD. OVERFUSING A
CIRCUIT CAN CAUSE A FIRE.
3. If preceding checks did not re-
veal the cause of malfunction,
then access to the control
panel is required per Figure
3.18. The first step in gaining
access is to remove the two
control knobs (A), then re-
move the (6) Phillips head
screws (B). Once the control
panel has been removed, you
need to remove the (2) Phil-
lips head screws (C). Then
pull the control mounting
bracket forward. This allows
access to the controls.

Troubleshooting Procedures

12 Volt Supply Wires
Figure 3.16
12 Volt Supply Check
Figure 3.17
Fuse Continuity Check
Figure 3.18
Controls Access
3-10