Samsung IPX-G5X0 series Installation Manual page 19

Table of Contents

Advertisement

SAMSUNG IPX-G5X0 Installation Manual v1.0
IPX-G520S/G540S (ECU) Basic Configuration
Use the following steps to connect to the serial console:
 Connect a serial cable to the console port of the system.
 Run a serial terminal program (I.E., PuTTY, etc.) on your PC and set the baud rate to 38,400.
 The default login ID is: admin / The default Password is: samsung*#
 Enter 'cli' to set up the basic gateway configuration.
 Select '1. Setup basic configuration'.
 Following the prompts enter the IP Address of the ECU, Gateway IP Address, and Subnet Mask.
 Enter the LAN IP Address of the main IPX-G500B, which this expansion cabinet will be connected to.
Note: The IPX-G520S/G540S LAN port should be connected to the same LAN network as the IPX0-G500.
 Assign the sequence number from 1 to 6 for this expansion cabinet. It should be unique for each
gateway.
 After all information is entered it will ask if you want to reset the system to apply the changes.
 To reboot the system enter 'yes', otherwise enter 'no'
######
1. Enter ECU IP Address (Enter Key : 10.251.0.11 ) :
2. Enter Gateway Address (Enter Key : 10.251.0.1
3. Enter Subnet Mask
######
1. Enter CMU IP Address (Enter Key : 10.251.0.10 ) :
1. Enter this ECU number (Enter Key : 1)
End of Configuration. To apply it, please restart the system.
Do you want to restart? (yes/no) :
Please enter [IP/Gateway/Subnet Mask] of this ECU
(Enter Key : 255.255.255.0 ) :
Please enter the IP Address of CMU
######
) :
######
:
Mar 2016