TABLE OF CONTENTS Important safety information Description of the appliance Using your appliance Installation 9-16 Cleaning and maintenance 17-18 Troubleshooting Technical data Declaration of conformity IMPORTANT: This User Instruction Manual contains important information, including safety & installation points, which will enable you to get the most out of your appliance. Please keep it in a safe place so that it is easily available for future reference;...
IMPORTANT SAFETY INFORMATION WARNING! Do not use or attempt to install this appliance until you have read this instruction manual. This appliance is intended for household use only. General Information This appliance is designed for domestic household use and designed be built into a standard ...
Page 4
Do not place or store flammable liquids, highly inflammable materials or fusible objects (eg. Plastic film, plastic or aluminium) on or near the appliance. Do not use or store flammable materials in the appliance storage drawer or near this ...
Electrical Caution CAUTION: Cleaning operations must only be carried out when the oven is cool and disconnected from the power supply. Any work on electric equipment and systems may only be carried out by authorized qualified persons. In case of any damage, switch off the appliance and disconnect it from the power supply ...
DESCRIPTION OF THE APPLIANCE Product Cut out size Approx. net Electrical Rated input Model Dimensions (w x d) mm weight connection power (h x w x d) mm SCG-6182B 112x590x510 555x475 13.6 kg 220-240V/50Hz...
USING YOUR APPLIANCE Igniting the Burners • To light the burner, turn the gas control knob to the High Flame setting of the burner to be lit, while at the same time depressing the gas control knob to activate the spark ignition.
Page 9
Burner and Utensil Choice The maximum utensil (pan) diameters in millimetres (mm) for each burner are: 1. For Natural Gas hotplates: Auxiliary (small) and Semi-Rapid (medium) = 195mm Rapid (large) = 230mm DCC (wok) = 300mm 2. For Universal LPG hotplates: Auxiliary (small), Semi-Rapid (medium) and Rapid (large) = 195mm DCC (wok) = 300mm The minimum utensil (pan) diameters in millimetres (mm) for each burner are:...
INSTALLATION The installation must be carried out by a suitably qualified person, in compliance with gas installation regulations, local electrical and building rules and specifications, and the instructions outlined in this manual. Before cutting into any benchtops, ensure the minimum clearances to walls, adjacent surfaces and overhead surfaces required by the relevant gas appliance installation code (see above) will comply.
IMPORTANT: This appliance must be installed in accordance with: • AS/NZS 5601 – Gas Installations (for Australia) AS/NZS 3000 – Electrical Installations (Wiring Rules) • Local gas fitting regulations, building codes and other relevant statutory • regulations. • Check the gas type label on the underside of the hotplate, adjacent to the gas connection to ensure it corresponds to the installation gas supply.
3. Fit burners and trivet Replace burners and ensure they are correctly repositioned over the ignitor (S) and thermocouple (T). The ignitor (S) must be clean for trouble free sparking. Test burner ignition and burner flame for correct operation. If the burner is placed correctly it will not rotate on its supports.
5. Gas connection Install in accordance with relevant gas standards and/or codes of practice applicable. Connect the elbow fitting to the appliance gas manifold connection and check that seals between the elbow and manifold connection are in place and in good condition. For Natural gas: connect the natural gas appliance regulator (pictured below) •...
Page 14
After connecting to gas, check for leaks using soapy solution, never a naked flame. • Fit the duplicate data plate (supplied in separate bag) on a surface adjacent to the • hotplate, for example, the inside of the cupboard door so it is clearly visible for any service technician.
Page 15
Gas Conversion (ULPG – NG) If the required gas conversion kit is not supplied with your appliance, Gas Conversion shall only be undertaken by authorised persons. The ULPG to NG conversion kit contains NG regulator Rapid Jet ø 1.55mm • •...
Page 16
Gas Conversion (NG - ULPG) If the required gas conversion kit is not supplied with your appliance, Gas Conversion shall only be undertaken by authorised persons. The NG TO ULPG conversion kit contains Test point adapter Rapid Jet ø 0.9mm •...
Page 17
Universal LPG 2.75 kPa Model Burners Type Injector Dia (mm) Nominal Gas Consumption SCG-6182B Auxiliary 0.53 3.6MJ/h Semi-Rapid 0.69 6.5MJ/h Rapid 10.8MJ/h 0.50 + 1.02 17.2MJ/h TOTAL NHGC (MJ/h) 33.8 Natural Gas 1.0 kPa Model Burners Type Injector Dia (mm)
CLEANING AND MAINTENANCE CAUTION! Cleaning operations must only be carried out when the hob has cooled down, especially when cleaning the enamelled parts. Trivets (utensil supports) Enamelled parts must only be washed with a sponge and soapy • water or with non-abrasive products. Rinse with clean water. Dry with soft cloth.
After each use Wipe the appliance over with a damp cloth. • Dry the appliance by rubbing the surface with a clean cloth. • IMPORTANT: DO NOT use any corrosive cleaning products or abrasive cleaners. Only clean with warm water and a small amount of washing-up liquid. CAUTION! Ensure the heating plate is clean.
TROUBLESHOOTING Servicing of the hotplates must only be done by an authorised service representative and the hotplate must not be modified. Power must be disconnected before any servicing or maintenance is conducted. Abnormal conditions include: Excessively yellow or sooting flame type. •...
TECHNICAL DATA Product Dimensions Cut out size Approx. net Electrical Rated input Model (h x w x d) (w x d) mm weight connection power SCG-6182B 112x590x510 555x475 13.6 kg 220-240V/50Hz -20-...