Panasonic KX-HNS103EX Installation Manual page 18

Home network system water leak sensor
Table of Contents

Advertisement

Setup
Installing the probe unit on a floor
When installing the probe unit on a floor, use the double-sided tape to attach the
probe unit directly to the floor.
Note:
R If the probe unit is inserted into the wall mounting adaptor and attached to a
floor, the probes will be too far from the floor and therefore water leaks can only
be detected after the leaked water has become deep enough to touch the
probes.
Correct installation
Shallow water touches probes
18
HNS103EX_(en_en)_0111_ver.105.pdf
Helpline Tel. No.: U.K. 0330 3331112 Ireland 01 4475228
18
Incorrect installation
Only deep water can touch probes
A
A Wall mounting adaptor
2017/01/11
18:37:55