LG THERMA V AHBW036H0 Installation Manual page 52

Air-to-water heat pump
Hide thumbs Also See for THERMA V AHBW036H0:
Table of Contents

Advertisement

System Set-Up
Code
Item
2B
Function
Description
Value #1 Note
Default
Range
Value #2 Note
Default
Range
Value #3 Note
Default
Range
2E
Function
Description
Value #1 Note
Default
Range
2F
Function
Description
Value #1 Note
Default
Range
※ Some contents may not be displayed depending on DIP switch setting in the Main PCB.
52 Air-to-Water Heat Pump
Sanitary water heating timers
Determine following time duration : operation time of sanitary tank
heating, stop time of sanitary tank heating, and delay time of
sanitary tank heater operating.
This time duration defines how long time sanitary tank heating can
5 ~ 95 min (step: 5 min)
This time duration defines how long time sanitary tank heating can
be stopped. It is also regarded as time gap between sanitary tank
0 ~ 600 min (step: 30 min)
This time duration defines how long time sanitary tank heater
will not be turned on in sanitary water heating operation.
20 ~ 95 min (step: 5 min)
Changing thermal on / off room air temp
Select Thermal on / off Temperature gap.
Thermal on
0
-0.5 °C
1
4 °C
2
2 °C
3
-1 °C
Changing thermal on / off leaving water Ten
Select Thermal on / off Temperature gap.
Thermal on
0
-2 °C
1
-6 °C
2
-2 °C
3
-1 °C
Detail
be continued.
30 min
heating cycle.
180 min
20 min
Thermal off
1.5 °C
6 °C
4 °C
1 °C
0
0 ~ 3
Thermal off
2 °C
4 °C
4 °C
1 °C
0
0 ~ 3
Remark

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents