S&G 2740B Operating Instructions Manual

S&G 2740B Operating Instructions Manual

Electromechanical safe lock

Advertisement

The S&G
2740B Model Electromechanical Safe Lock combines
©
and simplifies the familiar operation of a mechanical lock with
the advanced security features of a sophisticated electronic
device. Follow these instructions carefully to get the best service
from your lock.
I
ntroductIon
• The S&G
Model 2740B Electromechanical Safe Lock is
©
shipped from the factory in single user mode with a factory
shipping combination of 50-25-50. This combination is used
to open the lock and change the combination(s). You should
set the lock to your own, unique combination(s) before storing
anything of value in the safe or cabinet.
• All setup, maintenance, and troubleshooting operations must
be performed with the safe or container OPEN. Never close
the container with a change key inserted in the lock. At
the conclusion of a combination change or service operation
the lock should be checked to make sure it operates at least
three times consecutively on the intended combination before
closing the safe or container.
• The lock will sometimes emit a beep or series of beeps to
communicate its state. A table of the eleven possible beep
patterns is included in this document (page 11).
• All combinations must contain three numbers, ranging from
0 to 99. Unlike mechanical locks, the 2740 has no forbidden
zone, and it does not have a restriction on how close adjacent
numbers of the combination may be to one another.
• If you stop dialing for more than ten seconds, the lock will
reset, forcing you to begin the combination entry sequence all
over again.
• If ten incorrect combinations are entered in a row, the S&G
Model 2740B Electromechanical Safe Lock will shut
down for a period of ten minutes. Entering a correct
combination before reaching the tenth incorrect entry in
Sargent & Greenleaf, Inc.
PO Box 930
Nicholasville, KY 40340-0930
Phone: (800)-826-7652 Fax: (800)-634-4843
Phone: (859)-885-9411 Fax: (859)-887-2057
Copyright 2014, Sargent & Greenleaf
©
O
perating
S&G
Model 2740B Electromechanical Safe Lock
i
nstructiOns
a row resets the
wrong combination
counter. It doesn't
make any difference
how much time
intervenes between
consecutive wrong
combination entries.
However, entering a
correct combination
before reaching the
tenth incorrect entry
in a row resets the wrong combination counter. There is no
alternative to waiting for the penalty time to expire once it has
begun.
• The S&G
Model 2740B Electromechanical Safe Lock is
©
powered by a main battery (CR123A lithium camera-type),
and also uses a long-life backup battery (CR2450 coin cell).
Both batteries must be changed at the same time, preferably
by a technician who has successfully completed S&G factory
approved training.
• The 2740B will switch to the backup battery and latch OPEN if
the ten-beep low battery signal is repeatedly ignored. Opening
with the internal backup battery may take as long as five
seconds after the combination is entered. If you find that your
lock will not lock, the batteries will have to be replaced, and it
will need to be reset using a 444 Device.
• The lock's combination can be changed by use of a change
key. The change key can be used by a safe custodian or
security officer following the appropriate instructions included
in this document.
©
• Lock bodies and covers are matched components. Do not
replace a lock cover with the cover from another lock. At best,
this will produce erratic lock operation.
Sargent & Greenleaf S.A.
9, chemin du Croset
1024 Ecublens, Switzerland
Phone: +41-21 694 34 00
Fax: +41-21 694 34 09
Document 630-848
Revised 6/26/2014

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 2740B and is the answer not in the manual?

Questions and answers

Summary of Contents for S&G 2740B

  • Page 1 • The lock will sometimes emit a beep or series of beeps to communicate its state. A table of the eleven possible beep • The 2740B will switch to the backup battery and latch OPEN if patterns is included in this document (page 11).
  • Page 2: Table Of Contents

    Table of Contents Operating the 2740 Introduction to the 2740 ..........................front page Dialing Procedures Important Dialing Notes ..........................page 3 Opening the Lock in Single User Mode ......................page 3 Opening the Lock in Dual User Mode ......................page 3 Combination Changing Change Key ..............................page 4 Combination Changing Notes ........................page 4 Changing the Combination with the Change Key ..................page 4 Lock Setup and Maintenance Functions...
  • Page 3: Important Dialing Notes

    To re-lock the 2740B after the container is closed and its handle To re-lock the 2740B after the container is closed and its handle is turned to the fully locked position, turn the dial at least ½...
  • Page 4: Combination Changing

    OmbinatiOn hanging nstructiOns S&G Model 2740B Electromechanical Safe Lock ™ 4. Turn the dial left at least two complete revolutions, then stop hange precisely on the first number of the OLD combination. 5. Turn the dial right (clockwise), stopping when the second The original Model OLD combination number comes to the index.
  • Page 5: Lock Setup And Maintenance Functions Dial Calibration

    The key to success is to dial very, very precisely. The 2740B lock can be calibrated to zero anytime, and it’s a good idea to do so whenever you find it takes more than one or two attempts to dial open the lock, even though you are being very careful and staying focused while dialing.
  • Page 6: Lock Open Latch

    If the lock’s low battery warning signal is ignored for approximately one hundred consecutive openings, the 2740B will go into Lock Open Latch condition. It cannot be locked. To reset the Lock Open Latch, attach a fresh 9-volt battery to a Sargent & Greenleaf 444 Device (S&G part number 2740-444), then plug the device’s connector into the lock’s change key port on the outside of the cover.
  • Page 7 S&G Model 2740B Electromechanical Safe Lock ™ hangIng the atterIes continued 9. During a 10-second period following the initial beep, the lock will perform a battery check. You will hear another single beep if the 10-second battery check is successful. It is recommended that you wait for this beep before installing the cover onto the lock.
  • Page 8: Dual User Mode Function

    Dual user mode requires two different combinations to open the lock. After the first combination is entered, the second combination must be entered within two minutes to accomplish an opening. Here is the process to change the 2740B from single user mode to dual user mode: 1.
  • Page 9: Single User Mode Function

    Single user mode requires just one combination to open the lock. Here is the process to change the 2740B from dual user mode to single user mode: 1. Open the lock using the existing dual user combinations.
  • Page 10: Unknown Combination Function

    Continue turning the dial right to retract the lock bolt. 13. Remove the change key from the lock. The 2740B is now in single user mode, and will operate on your new combination.
  • Page 11: Beep Patterns

    The 2740B lock provides information to the user in the form of audible beeps. There are two kinds of beeps—a short, distinct beep and a long beep that is ten times as long as the standard beep. We refer to the long beep as a brap.
  • Page 12: Warranty

    S&G Model 2740B Electromechanical Safe Lock ™ WARRANTY Seller warrants that for five years from the date of shipment from Seller’s point of manufacture, the goods shall be free from defects in material and workmanship, provided the goods are normally and properly used according to the Seller’s written instructions.

Table of Contents