ERROR DETECTION

Error
Serial signal error
Indoor unit
thermistor error
Outdoor unit
thermistor error
Indoor unit control error
Outdoor unit
control error
Indoor fan motor error
Refrigerant cycle error
Optional function error
Model information error
2009.02.17
Indoor unit LED
Operation
Timer LED
LED
2 flash
3 flash
Off
4 flash
5 flash
8 flash
2 flash
2 flash
3 flash
2 flash
3 flash
3 flash
4 flash
4 flash
2 flash
2 flash
3 flash
5 flash
5 flash
6 flash
2 flash
6 flash
3 flash
2 flash
7 flash
3 flash
4 flash
2 flash
8 flash
4 flash
0.1 sec on/off 0.1 sec on/off 0.1 sec on/off
Wired
Error
remote
Coil dry
control
LED
off
01
Serial signal (reverse) error, at operation start up
off
01
Serial signal (reverse) error, during oeration
13
Serial signal (forward) error, at operation start up
off
off
13
Serial signal (forward) error, during operation
off
00
Wired remote control error
off
02
Indoor air thermistor error
off
04
Heat exchanger middle thermistor error
off
Discharge pipe thermistor error
0C
Heat exchanger thermistor error
off
06
Outdoor air thermistor error
off
0A
Manual auto button welded
off
20
17
Current trip error
off
off
18
CT abnormal
1A
Compressor location detection error
off
off
1B
Outdoor unit fan drive system abnormal
off
12
Abnormal lock (upper fan motor)
off
12
Abnormal rotation (upper fan motor)
off
0F
Discharge temperature abnormal
off
24
Cooling high pressure abnormal rise
2C
off
DC 4-way valve and expansion valve abnormal
off
19
Active filter abnormal (first time)
25
off
PFC circuit error
11
Model information error
10