1-1. FEATURE MODEL ASU9RLS ASU12RLS FEATURES Energy Efficiency MODEL ASU9RLS ASU12RLS Seasonal Energy Efficiency Ratio (SEER) Heating Seasonal Performance Factor (HSPF) MEASUREMENT CONDITIONS ANSI/ASHRAE STANDARD 37-1988 ALL DC fan motor V-PAM control Front view V-PAM technology makes a compressor more powerful.
Super quiet Air flow mode can be set in 4 steps and more detailed air flow setting is possible. Fan speed Noise level Quiet dB(A) Easy maintenance Easy maintenance and always clean. Troublesome maintenance has been made easy. Since the front panel is easy to remove, maintenance is also easy. Inner drying operation This model is equipped with an inner drying function.
1-2. WIRED REMOTE CONTROLLER FEATURES Four kinds of timer setup (ON / OFF / PROGRAM / SLEEP) are possible. Four kinds of timers. Easy operation. Built-in timers Select from four different timer programs (On/Off/Program/Sleep). Program timer The program timer operates the ON and OFF timer once within a 24 hour period. Sleep timer The sleep timer function automatically corrects the temperature thermostat setting according to the time setting to prevent excessive cooling and heating while sleeping.
Page 7
FUNCTIONS SLEEP button MODE button SET TEMP. button ( COIL DRY button Signal Transmitter TIMER MODE button TIMER SET ( ) button FAN button START/STOP button SET button(Vertical) SET button(Horizontal) SWING button RESET button TEST RUN button This button is used when installing the conditioner, and should not be used under normal conditions, as it will cause the air conditioner’s thermostat function to operate incorrectly.
1-7. FAN PERFORMANCE 1-7-1. AIR VELOCITY DISTRIBUTION MODEL: ASU9RLS, ASU12RLS Unit : ft/s (m/s) (ft) 6.56 TOP VIEW Note: FLOW CONTROL PANEL : Horiz. LOUVER :Center Fan speed : H i Operation : FAN 3.28 Voltage : 230V 6.6(2.0) 3.3(1.0) 1.6(0.5)
1-7-2. AIR FLOW MODEL: ASU9RLS, ASU12RLS COOLING Number of Fan speed rotations Airflow (r.p.m) HIGH 1320 1130 QUIET HEATING Number of Fan speed rotations Airflow (r.p.m) HIGH 1320 1130 QUIET - (01 - 11) -...
1-9. ELECTRIC CHARACTERISTICS ASU9RLS ASU12RLS 208/230 ~ Power Supply Max Operating Current *1)Wiring Spec. Connection Cable *1) Wiring Spec. Selected Sample (Selected based on Japan Electrotechnical Standard and Codes Committee E0005) - (01 - 14) -...
1-10. SAFETY DEVICES Model Protection form ASU9RLS ASU12RLS 3.15A 250V 3A 250V 215°F(102°C) Thermal protection Fan motor protection MAX.248±27°F(120±15°C) program - (01 - 15) -...
1-11. OPTIONAL PARTS Exterior Parts name Model No. Summary Fine dust, invisible mold spores, and harmful microorganisms are absorbed Apple-catechin onto the filter by static UTR-FA16 filter electricity, and further growth is inhibited and deactivated by the polyphenol ingredient extracted from apples. The filter deodorizes by powerfully decomposing absorbed odors using the...
11-1-1. WIRED REMOTE CONTROLLER FEATURES Various timer setup (ON / OFF / WEEKLY) are possible. Equipped with weekly timer as standard function. (2 times Start / Stop per day for a week) When setting up a timer, operation mode and a temperature setup can be changed.
FUNCTIONS START/STOP button Pressed to start and stop operation. Set temperature button Selects the setting temperature. Mode button Selects the operating mode(AUTO, HEAT, FAN, COOL, DRY). Fan button Selects the fan speed (AUTO, QUIET, LOW, MED, HIGH). Economy button* Turns the economy efficient mode on and off. Timer mode (CLOCK ADJUST) button* Selects the timer mode (OFF TIMER, ON TIMER, WEEKLY TIMER) Set the current time.
1-11-2. EXTERNAL CONNECT KIT This kit allows to operate the air conditioner, such as stopping and starting, using an external device, and output the operation status of the air conditioner. • Only operation and stop signals will be output. Use the remote control to check the operation mode, temperature, and airflow. Check the error information on the display area of the main unit.
Page 23
OPERATING OUTPUT SETTING • You can display air conditioner ON / OFF operation by external output. Signal specification • No voltage contact. • Contact capacity : Max. DC24V 10mA to 1A or less OPERATION Indoor unit status STOP SHORT External output signal OPEN Installation example For operation display...
2-1. SPECIFICATIONS Type INVERTER HEAT PUMP Model name AOU9RLS AOU12RLS Power source 208/230V ~ 60Hz Available voltage range 187-253V ~ 60Hz Starting current Cooling 1106 (1880) 1201 (2040) Airflow rate Heating 1059 (1800) 1059 (1800) Propeller fan × 1 Type × Q'ty Motor output Cooling Sound pressure level...
2-2. DIMENSIONS MODEL: AOU9RLS, AOU12RLS Unit : in. (mm) 21-1/4"(540) 4-29/32"(125) Top view 11-23/32(298) 31-3/32(790) 2-5/8(68) Side view Front view Side view MOUNTING POSITION Unit : in. (mm) 4" (100) or more 4" (100) or more 11-13/16"(300) or more If the space is larger that is stated, the condition will be the same as that are no obstacles. - (02 - 02) -...
2-7. AIR FLOW MODEL: AOU9RLS COOLING Number of rotations Air flow (r.p.m) 1880 1106 HEATING Number of rotations Air flow (r.p.m) 1800 1059 MODEL: AOU12RLS COOLING Number of rotations Air flow (r.p.m) 2040 1201 HEATING Number of rotations Air flow (r.p.m) 1800 1059...
2-10. SAFETY DEVICES Model Protection form AOU9RLS, AOU12RLS Current fuse 20A 250V (NEAR THE TERMINAL) Current fuse (MAIN PRINTED Circuit protection 3.15A 250V CIRCUIT BOARD) Current fuse (BETWEEN OUTDOOR 5A 250V UNIT AND INDOOR UNIT) Fan motor Thermal protection OFF:212 °F OFF:100 °C...