1

About this document

1.1 Function . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1
1.2 Target group: authorised qualified personnel. . . . . . . . . . . . . . . . . .1
1.3 Explanation of the symbols used . . . . . . . . . . . . . . . . . . . . . . . . . . .1
1.4 Appropriate use . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1
1.5 General safety instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1
1.6 Warning about misuse . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1
1.7 Exclusion of liability . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
2
Product description
2.1 Ordering code . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
2.2 Special versions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
2.3 Destination and use . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
2.4 Technical data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
2.5 Safety classification . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
3
Mounting
3.1 General mounting instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
3.2 Mounting of the actuator . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
3.3 Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
4
Electrical connection
4.1 General information for electrical connection. . . . . . . . . . . . . . . . . .4
4.2 Contact variants . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
5
Set-up and maintenance
5.1 Functional testing. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
5.2 Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
6
Disassembly and disposal
6.1 Disassembly. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
6.2 Disposal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
7
EU Declaration of conformity
1. About this document
1.1 Function
This operating instructions manual provides all the information you
need for the mounting, set-up and commissioning to ensure the safe
operation and disassembly of the safety switchgear. The operating
instructions must be available in a legible condition and a complete
version in the vicinity of the device.
1.2 Target group: authorised qualified personnel
All operations described in this operating instructions manual must
be carried out by trained specialist personnel, authorised by the plant
operator only.
Please make sure that you have read and understood these operating
instructions and that you know all applicable legislations regarding
occupational safety and accident prevention prior to installation and
putting the component into operation.
The machine builder must carefully select the harmonised standards
to be complied with as well as other technical specifications for the
selection, mounting and integration of the components.
1.3 Explanation of the symbols used
Information, hint, note:
This symbol is used for identifying useful additional information.
Caution: Failure to comply with this warning notice could
lead to failures or malfunctions.
Warning: Failure to comply with this warning notice could
lead to physical injury and/or damage to the machine.
1.4 Appropriate use
The products described in these operating instructions are developed to
execute safety-related functions as part of an entire plant or machine. It
is the responsibility of the manufacturer of a machine or plant to ensure
the correct functionality of the entire machine or plant.
The safety switchgear must be exclusively used in accordance with
the versions listed below or for the applications authorised by the
manufacturer. Detailed information regarding the range of applications
can be found in the chapter "Product description".
1.5 General safety instructions
The user must observe the safety instructions in this operating
instructions manual, the country-specific installation standards as well
as all prevailing safety regulations and accident prevention rules.
Further technical information can be found in the Schmersal
catalogues or in the online catalogue on the Internet:
www.schmersal.net.
The information contained in this operating instructions manual is
provided without liability and is subject to technical modifications.
There are no residual risks, provided that the safety instructions as well
as the instructions regarding mounting, commissioning, operation and
maintenance are observed.
1.6 Warning about misuse
In case of improper use or manipulation of the safety switch-
gear, personal hazards or damages to machinery or plant
components cannot be excluded when safety switchgear is
used. The relevant requirements of the standard ISO 14119
must be observed.
EN
AZ 16ZI
1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the AZ 16ZI and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for schmersal AZ 16ZI

  • Page 1: Operating Instructions

    2.3 Destination and use ........2 Further technical information can be found in the Schmersal 2.4 Technical data .
  • Page 2 6 A gG D-fuse ➁ M12 x 1 connector LHS Latching force: approx. 30 N for AZ 16ZI-1747, M12 x 1 connector RHS up to approx. 100 N for AZ 16ZI-2053 Actuator: Positive break travel: 8 mm ➂ Straight actuator...
  • Page 3 Operating instructions Safety switch AZ 16ZI 3.2 Mounting of the actuator 3.3 Dimensions All measurements in mm. The marks on the used actuator opening of the safety switch and on the actuator must be opposite. Provide for a direct positive linkage between the actuator and the safety guard.
  • Page 4 1 NO / 2 NC with connector 4 5 6 7 8 Information about the switch travel can be found in the online catalogue on the Internet: www.schmersal.net. 5. Set-up and maintenance Flexible actuator B6L 5.1 Functional testing The safety function of the safety components must be tested. The ¤5.5...
  • Page 5 Möddinghofe 30 42279 Wuppertal Place and date of issue: Boituva, September 16, 2016 Authorised signature Marco Antonio De Dato Head of Engineering and Design The currently valid declaration of conformity can be downloaded from the internet at www.schmersal.net.
  • Page 6 Production site: ACE Schmersal K.A. Schmersal GmbH & Co. KG Eletroeletrônica Industrial Ltda. Möddinghofe 30, D - 42279 Wuppertal Av. Brasil, nº 815 Postfach 24 02 63, D - 42232 Wuppertal Jardim Esplanada – CEP: 18550-000, Boituva – SP Brazil...