RSSI Filter
RSSIfilterThreshold=X, only tags with RSSI data above this threshold will be reported (typical
value -6500). Set to 0 to disable RSSI filtering
o This is a "filter" that allows users to configure the threshold above a given Received
Automatic decoding of SGTIN96 encoded data
DecodeSGTIN96=False - decodes encoded SGTIN96 EPC data into SGTIN13 (GTIN13 plus EPC
serial number)
AddSerialToDecodedGTIN13=True - includes the EPC serial number in GTIN13 decoded string
GTIN13SNseparator=0x2F - ASCII character to be used as separator between decoded
GTIN13 and serial number
GS1CompanyPrefixLength=6 - number of digits used for the GS1 Company Prefix Length
DecodeEPCMemory=False - output EPC data into EPC Tag URI (urn:epc:tag:...) format
o This setting allows MiniPad – rpad to automatic decode the tags EPC memory
Include TID on inventory reports
HidReportFormat=0 - set 0 to report EPC data only or 1 to report EPC+TID
HidReportSeparator=0x20 - ASCII character to be used as separator between EPC and TID in
HID reports
HidReportCRcharacter=0xD - ASCII character to be used as Carriage Return in HID reports
HidReportLFcharacter=0xA - ASCII character to be used as Line Feed in HID reports
o This setting allows MiniPad – rpad to automatic include the TID (Tag Unique ID) data
Include RSSI on inventory reports
IncludeRSSI=False - set True to include RSSI data at the end of HID report data
RSSIReportSeparator=0x23 - leading character to be used before RSSI information
o This setting allows MiniPad – rpad to automatic include the RSSI value (Received
© 2015-2017 – Identix Inc. All Rights Reserved.
Signal Strength Indication, the tags will be reported
(SGTIN96 format) data into to UPC / EAN-13 "human readable" barcode format.
in tag read reports.
Signal Strength Indication) in tag read reports