DANGER
Ultraviolet radiation. Follow instructions. Avoid overexposure. As with
natural sunlight, overexposure can cause eye and skin injury and
allergic reactions. Repeated exposure may cause premature aging of the skin and skin can-
cer. WEAR PROTECTIVE EYEWEAR; FAILURE TO MAY RESULT IN SEVERE BURNS OR
LONGTERM INJURY TO THE EYES. Medications or cosmetics may increase your sensitivity
to the ultraviolet radiation. Consult physician before using sunlamp if you are using medications
or have a history of skin problems or believe yourself especially sensitive to sunlight. If you do
not tan in the sun, you are unlikely to tan from the use of this product. Children, the elderly, or
fair skinned people who always burn easily and either never tan or tan minimally should not
use this equipment.
To use, lie down on bench and pull canopy down as far as adjustment will allow. Minimum use
distance from face tanner (if equipped) is 1 inch (2.5 centimeters), otherwise overexposure
may occur. Do not use without acrylic shields in place. Untanned persons should not tan on
consecutive days during their first week of tanning. Never tan more than once a day. Tanning
normally appears after the first few sessions and maximizes after approximately four weeks.
Tan once or twice per week thereafter to maintain appearance. Persons already having a base
tan may begin at advanced levels corresponding to the extent of their base tan.
Skin Type:
I
Sensitive Skin
(Burns easily and severely and does not tan.)
II Light Skin
(Burns easily and severely and tans minimally.)
III Normal Skin
(Burns moderately and tans average.)
IV Dark Skin
(Burns minimally, tans easily and above average.)
RECOMMENDED EXPOSURE TIMES IN MINUTES
Level 1/Week 1
Skin Type:
1st-3rd Sessions
I
Sensitive
II Light
4
III Normal
6
IV Dark
8
MAXIMUM EXPOSURE TIME IS 20 MINUTES
New lamps emit approximately 10% more ultraviolet radiation during the first 50 hours of opera-
tion. Recommended tanning times should therefore be reduced by approximately 10% during
that period.
WARNING: • Read these instructions before using this sunlamp product. • All persons in the
room should wear protective eyewear when lamps are on. Recommended eyewear: provided
eyeshields or equivalent eyewear as defined under 21 CFR 1040.20. Other types of eyewear
may not provide adequate protection. Failure to use protective eyewear may result in severe
burns or other eye injury. If discomfort develops, discontinue use and consult a physician.
THE FOLLOWING LAMPS HAVE BEEN CERTIFIED FOR USE IN THE 24S SERIES:
ETS ELITE Select Model F71-T12-100W BP (Full length lamps)
ETS ELITE Model F59-T12-80W BP (Short lamps in 24SF)
Heraeus E400 HPT (Facial unit lamps in 24SF)
DISCONNECT POWER CORD BEFORE ATTEMPTING TO CLEAN, RELAMP, OR
ENGAGE IN THE MAINTENANCE OF THIS PRODUCT.
THIS EQUIPMENT MUST BE EARTH GROUNDED.
This product is in conformity with performance standards for sun lamp products under 21 CFR
PART 1040.20 and ANSI/UL Standard 482.
Unpacking and Inspection
The canopy box contains the canopy and a pair of gas springs. The
bench box contains the bench, assembly hardware, stand legs and skirt.
Inspect the items and make sure they are free from any visible damage.
Report the extent of any damage to the transportation company.
Level 2
Level 3
Level 4
NOT RECOMMENDED FOR TANNING
8
12
16
10
15
20
12
16
20
Shock hazard.
Disconnect power before servicing or removing any protec-
tive covers.
Do not operate this device near water or while you are wet.
Some medications may increase your sensitivity to ultraviolet light.
It is recommended that you consult a physician before using this
sunbed if taking any medication or if you suspect that your skin
might be especially sensitive to sunlight.
Wear protective eyewear.
Failure to may result in severe burns or longterm injury to the eyes.
Use of a voltage source above 230V AC may prevent proper operation
of the sunbed and could cause damage and void the warranty.
Air from the room is used to cool the sunbed. Maximum ambient room
Level 5
temperature should be 80°F. Place your sunbed no closer than 6" from
any wall. Make sure nothing obstructs the airflow into the sunbed's
endcaps or out of the fan openings. A poorly ventilated room may
20
cause the unit to become hot and cause discomfort to the user.
20
20
Electrical Requirements
Your sunbed operates from a 220V AC source. The 24S requires a
NEMA 6-20R electrical outlet (below) on a dedicated circuit capable of
providing 20 Amp service, installed in the room in which you will use
the unit. We recommend installation by a professional electrician. The
outlet must be earth grounded.
Hardware Inventory
Allen-head Bolt 5/16" x 1"
Quantity 2
5/16" Metal Washer
Quantity 2
Bushing
Quantity 2
Allen-head Bolt 5/16" x 1 1/2"
Quantity 2
Nylon Washer
Quantity 2
DANGER
DANGER
WARNING
CAUTION
20 AMP NEMA #6-20R
RECEPTACLE
(These items and a small pillow)
Hex (Allen) Wrench
Quantity 1
Safety Goggles
Quantity 1
4930638-02 - Page 1
Hinge Brackets
(1) left, (1) right

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Sunvision 24S and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for ETS Sunvision 24S

  • Page 1 If discomfort develops, discontinue use and consult a physician. RECEPTACLE THE FOLLOWING LAMPS HAVE BEEN CERTIFIED FOR USE IN THE 24S SERIES: ETS ELITE Select Model F71-T12-100W BP (Full length lamps) ETS ELITE Model F59-T12-80W BP (Short lamps in 24SF) Heraeus E400 HPT (Facial unit lamps in 24SF)
  • Page 2 Assembly Procedures Remove the six 5/16” x 1” bolts and Turn bench over. Install hinge brackets 5/16” washers installed in the bench. to ends of bench such that the short Lay the bench upside down on the Attach the stand legs, with the two boss engages the stud above the bolt floor.
  • Page 3: Remote Ports

    On the front of each leg are two holes Peel the backing from the double- for skirt mounting brackets. Locate the sided tape on each skirt top bracket two brackets and attach them as shown and attach them to the skirt as shown. with two #10-32 x 1/2”...
  • Page 4 Scenario 2 - T-Max 3A with Wireless Scenario 5 - T-Max® Manager Series with wires In single sunbed installations, the T-Max® 1A and 3A can offer the As always, this tanning bed is fully compatible with a wired T-Max® same control as the T-Max® Manager, eliminating the need for a Man- system.
  • Page 5 Setting the address manually Before connecting your sunbed to the T-Max® Manager or T-Max® 1A or 3A, the address of your sunbed must first be set. Set the address manually as described below. Setting the Address 1 Make sure the sunbed display is showing “0”. 2 Press the red stop button and, without releasing it, press the green timer button and hold both for three seconds.
  • Page 6 1 Remove the acrylic shield, metal grill and lamps. The following lamps have been certified for use in the 24S series: ETS ELITE Select Model F71-T12-100W BP (Full length lamps) 2 With a soft cloth, wipe the entire length of each lamp.
  • Page 7: Troubleshooting

    Hour Counter This sunbed incorporates an ingenious hour counter function into the timing circuitry. It allows the operator of the unit to monitor the hours of use of the lamps, making it easy to determine when to change them. You may also decide to use this function to monitor other time based maintenance tasks.
  • Page 8: Limited Warranty

    LIMITED WARRANTY JK Products & Services (JK) warrants your tanning unit to be free of structural defects in material and workmanship, under normal use, for its lifetime. JK will, at its discretion, repair any structural defect which materially affects the performance of the tanning unit, or replace the tanning unit.