Page 1
Assisting the automation industry since 1986 User manual DATA RECORDER SRD-99 Firmware: v.3.34 b1 or higher • Loggy Soft: v.1.9.0 or higher • S-Toolkit: v.2.0.23 or higher • Read the user's manual carefully before starting to use the unit or software.
User manual - DATA RECORDER SRD-99 and cooperating software CONTENTS I. USER MANUAL FOR DATA RECORDER..............4 1. BASIC REQUIREMENTS AND USER SAFETY..................4 2. GENERAL CHARACTERISTICS........................5 3. TECHNICAL DATA............................7 4. DEVICE INSTALLATION..........................10 4.1. UNPACKING............................10 4.2. ASSEMBLY............................10 4.3. CONNECTION METHOD.........................13 4.3.1.Connections of current type inputs ( I version )...............16...
Page 3
User manual - DATA RECORDER SRD-99 and cooperating software 7.5. MAIN MENU STRUCTURE......................59 8. DOWNLOADING DATA FROM DATA LOGGER..................61 8.1. MODBUS (RS485) DATA DOWNLOAD..................61 8.2. USB FLASH DRIVE (PENDRIVE) DATA DOWNLOAD..............61 9. THE MODBUS PROTOCOL HANDLING....................64 9.1. LIST OF REGISTERS........................64 9.2.
User manual - DATA RECORDER SRD-99 and cooperating software Explanation of symbols used in the manual: - This symbol denotes especially important guidelines concerning the installation and operation of the device. Not complying with the guidelines denoted by this symbol may cause an accident, damage or equipment destruction.
User manual - DATA RECORDER SRD-99 and cooperating software 2. GENERAL CHARACTERISTICS • Multifunctional Device is designed for recording, displaying current or averaged values and presentation of technological parameter trends in graphic form. • Large data storage capacity The registered measurement results are recorded in the unit's memory. The...
Page 6
User manual - DATA RECORDER SRD-99 and cooperating software • Wide range of power supply voltage and external sensor power supply The built-in pulse power supply allows power to be supplied to the unit with 85...230...260V AC/DC voltage or 16...24...35 AC, 19...24...50 DC voltage (depending on version).
User manual - DATA RECORDER SRD-99 and cooperating software 3. TECHNICAL DATA Power supply voltage 85...230...260V AC/DC; 50 ÷ 60 Hz (separated) (depending on version) or 19... 24 ...50V DC and 16V... 24 ...35V AC (separated) External Fuse (required) T - type, max. 2 A Power consumption typically 7 VA;...
Page 8
User manual - DATA RECORDER SRD-99 and cooperating software Safety requirements according to: PN-EN 61010-1 installation category: II pollution degree: 2 voltage in relation to ground: 300V AC insulation resistance: >20MΩ insulation strength between power supply and input/output terminal: 1min. @ 2300V (see Fig. 3.1)
Page 9
User manual - DATA RECORDER SRD-99 and cooperating software This is a class A unit. In a residential or a similar area it can cause radio frequency interference. In such cases the user can be requested to use appropriate preventive measures.
User manual - DATA RECORDER SRD-99 and cooperating software 4. DEVICE INSTALLATION The unit has been designed and manufactured in a way assuring a high level of user safety and resistance to interference occurring in a typical industrial environment. In order to take full advantage of these characteristics installation of the unit must be conducted correctly and according to the local regulations.
Page 11
User manual - DATA RECORDER SRD-99 and cooperating software 90,5 mm 13 mm 8 mm 8 mm 13 mm max. 5 mm 1 mm 1 mm Fig. 4.1. Recommended mounting hole dimensions 92 mm max. 5 mm Fig. 4.2. Allowable mounting hole dimensions...
Page 12
User manual - DATA RECORDER SRD-99 and cooperating software 92 mm removable terminals 10 mm 12 mm NOTE: I version - removable terminals 8 mm RTD version - immovable terminals Fig. 4.3. Installing of brackets, and dimensions of connectors. GOOD...
User manual - DATA RECORDER SRD-99 and cooperating software 115 mm Fig. 4.5. Minimum distances when assembly of a number of units 4.3. CONNECTION METHOD Caution - Installation should be conducted by qualified personnel. During installation all available safety requirements should be considered. The fitter is responsible for executing the installation according to this manual, local safety and EMC regulations.
Page 14
User manual - DATA RECORDER SRD-99 and cooperating software - If the unit is equipped with housing, covers and sealing to, protecting against water intrusion, pay special attention to their correct tightening or clamping. In the case of any doubt consider using additional preventive measures (covers, roofing, seals, etc.).
Page 15
User manual - DATA RECORDER SRD-99 and cooperating software Depending on version: 85...230...260V AC/DC or 19...24...50V DC; 16...24...35V AC FUSE Fig. 4.7. Connection of power supply RS-485 12 13 RS-232/485 interface Fig. 4.8. Connection of RS-485 transmission signals digital input...
User manual - DATA RECORDER SRD-99 and cooperating software 4.3.1. Connections of current type inputs ( I version ) 10 11 12 13 14 n.c. DATA+ DATA- DIN- DIN+ GND- RS digital input RS-485 Power supply (depending on version) additional terminals...
User manual - DATA RECORDER SRD-99 and cooperating software When 2-wires connection is used, the resistance of particular wires (Ra ÷ Rc) NEEDN'T BE DIFFERENT (should be as small as possible) When 3-wires connection is used, the resistance of particular wires (Ra ÷ Rc) MUST BE IDENTICAL to enable proper compensation of it's resistance.
User manual - DATA RECORDER SRD-99 and cooperating software 5. FRONT PANEL DESCRIPTION display programming ENTER pushbuttons MENU Key designation and functions Symbols used in the manual: [ESC/MENU] Functions: MENU • go to main menu (press and hold by at least 2 sec.), •...
User manual - DATA RECORDER SRD-99 and cooperating software 6. PRINCIPLE OF OPERATION After turning the power supply on, the logo and basic unit data are showed on the display, then the unit goes to the measurement mode. 6.1. MEASUREMENT MODE...
User manual - DATA RECORDER SRD-99 and cooperating software 6.1.2. Measurement ranges definition of voltage inputs ( U version ) The nominal range of input current for each input is 0-5V, 1-5V, 0-10V or 2-10V and can be extended to the maximum of 0-12 V, independently to each measurement channel. The range of measurement results corresponding to the nominal range of input voltage is defined as user defined range.
User manual - DATA RECORDER SRD-99 and cooperating software 6.1.4. Measurement ranges definition of TC inputs ( TC version ) The range of every input's measured signal is defined by selecting sensor type and specified as user defined range. All values presented in graphic form (graphs, sliders) are scaled due to user defined range.
Page 23
User manual - DATA RECORDER SRD-99 and cooperating software ”Rec.period” parameter ”Rec.period” parameter ..t(a) t(c) t(b) Δt Explanation : t(a), t(b), t(c) - recording points a, b, c, d - measurement points Δt - delay between measurements: 0.125s ( I version ) or 2.5s ( RTD version ) Fig.
User manual - DATA RECORDER SRD-99 and cooperating software 6.2. MODES OF RESULT PRESENTATION The results of measurements conducted for active channels are presented in numeric or graphic (graph or bar) form. Selection of one of the available results presentation modes can be made using the [^] and [v] keys in the measurement mode.
User manual - DATA RECORDER SRD-99 and cooperating software After starting the unit the result presentation mode and channel selected prior to switching off the unit are active (this information is stored in the EEPROM memory) 6.2.1. "Single channel" mode This mode ( Fig.
User manual - DATA RECORDER SRD-99 and cooperating software channel name current date current time unit name channel number warning message informing that input allowable arrow indicates range is exceeded exceeding of user defined range percentage value of exceeding Fig. 6.13. Exceeding allowable range in "Single channel" mode Functions of keys in "Single channel"...
Page 27
User manual - DATA RECORDER SRD-99 and cooperating software channel name unit name channel number recorded overload recording date and time recorded measurements date and time of current measurement current measurement (displayed in negative mode) (not recorded yet) Fig. 6.14. Unit in “Measurements list” measurement results presentation mode.
Page 28
User manual - DATA RECORDER SRD-99 and cooperating software In the case of recording averaged values all indications in the " Measurements list " mode concerning values recorded in the unit's memory, constitute averaged values of measurement results. The current value indications concern only momentary measurement values.
User manual - DATA RECORDER SRD-99 and cooperating software 6.2.3. ”Graph” mode Values displayed in this mode depend on the set type of recorded value (see description of parameters "Channel 1"..."Channel 8" in the "Logging setup" menu). In the case of recording momentary values in this mode ( Fig. 6.17 ) the display shows measurement results in the form of a graph, numeric form and in the form of a vertical bar.
Page 30
User manual - DATA RECORDER SRD-99 and cooperating software The display shows points corresponding to measurement results. Directly after switching to the "Graph" mode the display shows points of the graph corresponding to measurement results recorded so far. The points that are displayed next, correspond to the results of conducted measurements.
User manual - DATA RECORDER SRD-99 and cooperating software If the settings of the horizontal scale (time scale) will be too big (time/point) in relation to speed of changes of the measurement signal, the graph can become illegible. If this is the case, change the time scale settings. The horizontal scale settings (time scale) can be changed in the "Graph options"...
Page 32
User manual - DATA RECORDER SRD-99 and cooperating software current time current date channel number measure result in graphical mode (bargraph) channel name arrow informs about direction of user defined range exceeding percentage rate of measure result to user defined range Fig.
User manual - DATA RECORDER SRD-99 and cooperating software 6.3. PRINCIPLE OF OUTPUTS OPERATION Device is equipped in electronic relay outputs that can be used to control external devices. Each output has own icon (in left upper corner Fig. 6.25 ) that shows the status of the output.
User manual - DATA RECORDER SRD-99 and cooperating software 6.3.2. Outputs control Device outputs are controlled by logic function of channels alarms. There are two logic functions: OR – closes (or opens, if output channel mode is set to N.C.) the relay when any of attached channels is in alarm state, AND - closes (or opens, if output channel mode is set to “N.C.”) when all of attached channels are in alarm state.
Page 35
User manual - DATA RECORDER SRD-99 and cooperating software Logic function time Relay state Closed Open time Close hold time Open hold time Fig. 6.29. Working relay diagram in ”N.O.” mode. ”Open hold time” and ”Closed hold time” greater than 0, ”Open delay” and ”Close delay” equals 0.
User manual - DATA RECORDER SRD-99 and cooperating software In case of often threshold overpass (large readings oscillations) the ” Close delay ” and ”Open delay” parameters in opposite to ”Closed hold time” and ”Open hold time” will delay switching output state until internal time counter reaches entered value. The counter is counting up (to the entered value) when logic function is 1 and counting down to 0 when logic function is 0 .
User manual - DATA RECORDER SRD-99 and cooperating software Output 2 (cooler control) ”Mode” - ”N.O.” ” Logic funct. ” - ”AND” ”Source:channel 1” - ”alarm 2” - cooler alarm ” Close delay ” - ”120.0” - cooler turning on delay ”Open delay”...
Page 38
User manual - DATA RECORDER SRD-99 and cooperating software edited password position is outlined and blinking Fig. 7.2. Password requested when accessing unit's main menu. presently configured current submenu name measurement channel number list position indicator presently selected item (edited parameter) current settings Fig.
User manual - DATA RECORDER SRD-99 and cooperating software 7.1. PARAMETERS EDITION To start edition of any parameter user should select name of desired one using [^] [v] buttons and then [ENTER]. 7.1.1. Numeric and switching parameters ("LIST" - type) Numeric parameters constitute a series of digits that form a number in decimal format.
User manual - DATA RECORDER SRD-99 and cooperating software 7.1.2. Text parameters Text parameters constitute a series of characters selected from the character table (Fig. 7.7) stored in the unit's memory. Entering the new parameter value (Fig. 7.6, 7.7) consists of selecting consecutive characters of the text by indicating the position of the character in the table displayed below edited text.
User manual - DATA RECORDER SRD-99 and cooperating software Functions of keys when editing selected character (at this time characters table is displayed below the edited parameter): • Selecting the character from the given line of characters table for the edited position of the text parameter.
User manual - DATA RECORDER SRD-99 and cooperating software 7.2. DESCRIPTION OF RESULTS PRESENTATION MODES MENU Press the [ESC/MENU] key in the current results presentation mode to go to the results presentation mode configuration menu. 7.2.1. "Measurements list options" menu This menu ( Fig.
User manual - DATA RECORDER SRD-99 and cooperating software ”Date”,”Time” - these options are available when the " List type " parameter was set as "historic" and define the position of the horizontal line (located in the lower part of the display) in relation to the recorded measurements results displayed on the list.
User manual - DATA RECORDER SRD-99 and cooperating software 7.3. RESULTS PRESENTATION MODES MENU STRUCTURE Main menu Power on Initialization MENU Channel selection Mode: ”Single channel” ENTER MENU Parameter MENU Mode: ”Measurements list” Measurements list options List type edition ENTER...
User manual - DATA RECORDER SRD-99 and cooperating software 7.4. MAIN MENU DESCRIPTION 7.4.1. ”Device information” menu This menu contains information about the unit and cannot be edited: ”Version” version of unit firmware, ”Serial no” unit serial number, ”Memory” unit's memory size, ”Used”...
User manual - DATA RECORDER SRD-99 and cooperating software If the display backlight is inactive and the “Backlight” option was set as “ temporary ” pressing any key will only switch the backlight on. Fig. 7.14. ”Display options” menu 7.4.3. ”Logging setup” menu This menu contains options defining the recording method and recorded channels: ”Write”...
Page 47
User manual - DATA RECORDER SRD-99 and cooperating software Fig. 7.16. Warning in “cyclic” recording mode ”Triggering” - method of recording measurement results. The following options are available: ”always” - measurements are recorded in time intervals defined by the “Recording period” parameter, ”high level”...
User manual - DATA RECORDER SRD-99 and cooperating software ”disabled” - data from the selected measurement channel will not be recorded, ”current v.” - current values (corresponding to the results of current measurements) will be recorded for the selected measurement channel, ”average v.”...
User manual - DATA RECORDER SRD-99 and cooperating software 7.4.5. ” Input settings ” menu (common parameters) This menu enables the configuring of current inputs. The number of the configured input is displayed in the upper part of the display (Fig. 7.19).
User manual - DATA RECORDER SRD-99 and cooperating software 7.4.6. ”Input settings” menu ( I version ) ”Unit” - 4-character sequence constituting the unit for the value measured on the given channel. Fig. 7.20. ”Inputs settings” (part 1) ”Input type”...
User manual - DATA RECORDER SRD-99 and cooperating software ”Upper ext.” (Fig. 7.20). - parameter defining the allowable range of input currents If the input current lies within the defined range then the appropriate ”Lower ext.” measurement result shall be displayed despite exceeding the nominal measurement value 0-20 mA or 4-20 mA.
Page 52
User manual - DATA RECORDER SRD-99 and cooperating software - these parameters define the values displayed for maximum (Hi), and ”Hi value” minimum (Lo) voltage of user defined range (0-5 V, 1-5 V, 0-10 V or ”Lo value” 2-10 V). The aforesaid parameters can be set in the range - 9999 ÷ 9999.
User manual - DATA RECORDER SRD-99 and cooperating software ”Upper ext.” = 1 V ”Lower ext.” = 1 V user defined range (2-10 V) permissible measurement range measurement result is displayed regardless on nominal range exceeding display display message ”-Lo-”...
User manual - DATA RECORDER SRD-99 and cooperating software 7.4.9. ” Outputs settings ” menu This menu allows to change settings of the outputs. ” Mode ” - Defines operation mode of the output. The following options are available: ” inactive ”...
User manual - DATA RECORDER SRD-99 and cooperating software • All time type parameters which describe outputs, can be set in range 0 ÷ 9999 with resolution of 1 sec. • Because of computing precision, the time is shorter about 2.5% than the entered value.
User manual - DATA RECORDER SRD-99 and cooperating software 7.4.11. ”RS485 port settings” menu This menu contains options to configure the RS-485 interface: ”Address” - this parameter specifies the unit’s address, according to the Modbus protocol (in the range of 0 to 99). If the address is set as 0, then the unit responds to the FFh address.
User manual - DATA RECORDER SRD-99 and cooperating software Fig. 7.30. “RS485 port settings” menu 7.4.12. ”Access setup” menu This menu contains options controlling access to the unit’s adjustable parameters and to data downloading function (using USB Host port): ”Password for menu access” - menu access password (4-digit number). If the parameter is set to “0000”...
User manual - DATA RECORDER SRD-99 and cooperating software After selection one of options above device waits for plugging in of FlashDrive. If disk is found then device displays the message which allows approving or cancelling selected operation. Fig. 7.32. “USB options” menu To return to ”USB options”...
User manual - DATA RECORDER SRD-99 and cooperating software 7.5. MAIN MENU STRUCTURE Result presentation mode MENU Press and hold at least 2 seconds MENU 0 _ _ _ 4-digit user password entering (if it is different from „0000”) ENTER...
Page 60
User manual - DATA RECORDER SRD-99 and cooperating software See previous page ENTER ENTER Parameter MENU Output settings Mode edition ENTER MENU Logic funct. MENU ENTER ENTER Parameter Source Channel 1 edition ENTER MENU Close delay MENU Channel 2 ... Channel 7...
User manual - DATA RECORDER SRD-99 and cooperating software 8. DOWNLOADING DATA FROM DATA LOGGER 8.1. MODBUS (RS485) DATA DOWNLOAD To download data form the data logger connect it to PC via USB/RS-485 or RS-232/RS- 485 serial converter and use Loggy Soft delivered with the device.
Page 62
User manual - DATA RECORDER SRD-99 and cooperating software After successful data write the following message will appear, which has to be confirmed by pressing ENTER key: In order to transfer logged data to the PC, connect FlashDrive to PC and use Loggy Soft .
Page 63
User manual - DATA RECORDER SRD-99 and cooperating software 2) When pendrive is formatted using default Windows standards and manual write mode is selected (file writing can be forced but it may cause errors) 3) When pendrive is formatted not in accordance with Tab. 8.1 (file writing not done)
User manual - DATA RECORDER SRD-99 and cooperating software 9. THE MODBUS PRO TOCOL HANDLING Transmission parameters: 1 start bit, 8 data bits, 1 stop bit, no parity control Baud rate: selectable from: 1200 to 115200 bits/second Transmission protocol: MODBUS RTU compatible The device parameters and measurement result are available via RS-485 interface, as HOLDING-type registers of Modbus RTU protocol.
Page 65
User manual - DATA RECORDER SRD-99 and cooperating software Register Write Range Register description Control registry for time-related settings: 0 - starting continuous updating of registries 18h ÷ 1Eh by the internal clock (current time and date), 80h - stopping continuous updating of registries 18h ÷ 1Eh by the internal clock (automatically after writing one of 18h ÷...
Page 66
User manual - DATA RECORDER SRD-99 and cooperating software Register Write Range Register description Written memory in kB Approximated time remaining until memory is filled with recorded measurement results – Higher (2 ) byte (parameter in seconds). Approximated time remaining until memory is filled with recorded measurement results –...
Page 67
User manual - DATA RECORDER SRD-99 and cooperating software Register Write Range Register description “Name” parameter in “Inputs settings” submenu for channel 1; Character Higher byte – character No. 7; Lower byte – character No. 8 “Name” parameter in “Inputs settings” submenu for channel 1;...
Page 68
User manual - DATA RECORDER SRD-99 and cooperating software Register Write Range Register description Alarm parameters in “Inputs settings” submenu for channel 5; Register from E0h to E5h registry description like for channel 1 (see registers C0h to C5h). Alarm parameters in “Inputs settings” submenu for channel 6;...
User manual - DATA RECORDER SRD-99 and cooperating software Register Write Range Register description Parameters in “Outputs settings” submenu for output 2; registry Register from 110h to 11Dh description like for output 1 (see registers 100h to 10Dh). - if the measurement result exceeds the allowable measurement range defined by "Hi value", "Lo value" and “Upper ext.”, “Lower ext.”...
User manual - DATA RECORDER SRD-99 and cooperating software 9.3. EXAMPLES OF QUERY/ANSWER FRAMES The examples concern a unit with address 1. All values are given in the hexadecimal system. Designations: ADDR Address of the device in the system FUNC...
Page 71
User manual - DATA RECORDER SRD-99 and cooperating software The answer: ADDR FUNC BYTE C DATA H,L CRC L,H DATA H, L - displayed value = 255, no decimal point. Decimal point position can be read from reg. 43h (position of decimal point for channel 1) 4.
Page 72
User manual - DATA RECORDER SRD-99 and cooperating software b) The answer (if an error occur): ADDR FUNC CRC L,H ERR - error code (08 - registry writing blocked by “Config change” parameter in “RS485 port settings ” menu) 6. Change of baud rate of all devices connected to the net (BROADCAST message).
User manual - DATA RECORDER SRD-99 and cooperating software 10. USER'S SETTINGS LIST Description Parameter Description Value page Parameters in the "Measurements list options” menu List type Type of measurement results list Date, Time Position of time line on historical list Parameters in the "Graph options”...
Page 74
User manual - DATA RECORDER SRD-99 and cooperating software Description Parameter Description Value page Unit Unit for measured value Input type Type of input/sensor 50, 53 Value displayed for maximum value of input Hi value 50, 53 current Value displayed for minimum value of input...
Page 75
User manual - DATA RECORDER SRD-99 and cooperating software Description Parameter Description Value page Hysteresis 2 Hysteresis of alarm 2 Settings for Channel 3 in “Inputs settings” menu Name Measurement channel name Unit Unit for measured value Input type Type of input/sensor...
Page 76
User manual - DATA RECORDER SRD-99 and cooperating software Description Parameter Description Value page Hysteresis 1 Hysteresis of alarm 1 AL2 mode Alarm 2 generation mode Threshold 2 Threshold of alarm 2 Hysteresis 2 Hysteresis of alarm 2 Settings for Channel 5 in “Inputs settings” menu...
Page 77
User manual - DATA RECORDER SRD-99 and cooperating software Description Parameter Description Value page Lower ext. Lower extension of measurement range AL1 mode Alarm 1 generation mode Threshold 1 Threshold of alarm 1 Hysteresis 1 Hysteresis of alarm 1 AL2 mode...
Page 78
User manual - DATA RECORDER SRD-99 and cooperating software Description Parameter Description Value page Filter Level of filtration of indications Bias Shifting of measurement scale Upper ext. Upper extension of measurement range Lower ext. Lower extension of measurement range AL1 mode...
Page 79
User manual - DATA RECORDER SRD-99 and cooperating software Description Parameter Description Value page Source: channel 7 Channel 7 alarm state source Source: channel 8 Channel 8 alarm state source Close delay Close switch delay time Open delay Open switch delay time...
User manual - DATA RECORDER SRD-99 and cooperating software II. USER MANUAL FOR “ LOGGY SOFT ” System requirements: At least i486 computer, Colour monitor with minimum resolution of 640 x 480, 20 MB of free hard drive space. Designed for Windows...
Page 81
User manual - DATA RECORDER SRD-99 and cooperating software Fig. 2.1. Selection of serial port and baud rate After defining the communications port and baud rate, go to device detection screen ( Fig. 2.2 ) by clicking on the [Next>>] button.
Page 82
User manual - DATA RECORDER SRD-99 and cooperating software Fig. 2.2. Scanning network for devices The list shown on the figure (Fig. 2.2) contains one detected device. Order of devices on the list corresponds to the order of addresses assigned by the user to individual devices. Once all devices are detected press [Break scanning] button.
User manual - DATA RECORDER SRD-99 and cooperating software 3. USING THE PROGRAM Upon application startup the Current measurement menu is displayed ( Fig. 3.1 ). Fig. 3.1Program window upon startup The selection from the currently active menu is made using the flat buttons in the upper part of the program window ( Fig.
User manual - DATA RECORDER SRD-99 and cooperating software 3.1. „ CURRENT MEASUREMENT ” MENU Current measurement menu allows to view current measurements results in table format. This table contains measures of channels of all installed devices. Only the measurements from devices installed using the RS-485 interface will be available. To enable continuous reading of data from the devices check Enable current measurement mode .
Page 85
User manual - DATA RECORDER SRD-99 and cooperating software 3.2.1. „ Table ” tab Fig. 3.3. Reports - menu The Table tab (Fig. 3.3) is used for printing information concerning recorded measurements (e.g. temperature, humidity) in the form of a table for one of the groups or a particular measurement channel selected by the user (for more information on groups see 3.3.2 section,...
Page 86
User manual - DATA RECORDER SRD-99 and cooperating software Selecting table type (for a group or single channel) In order to select table type: • click appropriate tab Groups or Channels (Fig. 3.3), • check specific group or measurement channel. This will display measurement results for the selected group or single channel (displaying results takes place automatically after each change of group or measurement channel).
User manual - DATA RECORDER SRD-99 and cooperating software 3) The time can be changed by clicking on the box, in which it is displayed and manually typing it in using the keyboard. 4) The operation is completed by pressing the [Refresh] button; this will update the data shown in the table.
Page 88
User manual - DATA RECORDER SRD-99 and cooperating software [Refresh] button • - updates the displayed data; • Show cursor field - check this field to activate special graphical cursor which allows to track measurement points of the selected channel graph.
Page 89
User manual - DATA RECORDER SRD-99 and cooperating software Fig. 3.7. Enlarging graph moving the graph • - the graph can be moved to the left/right (earlier/later time period, correspondingly). In order to do this, right-click on the graph and drag the pointer in desired direction (Fig.
Page 90
User manual - DATA RECORDER SRD-99 and cooperating software • measurement points tracking - if Show cursor field is checked then special graphical cursor is displayed on the graph. This cursor allows to easy tracking of measured data. Colour of the cursor is same as selected channel colour.
Page 91
User manual - DATA RECORDER SRD-99 and cooperating software Information on periodical lack of measurement If any measurement channel, for whatever reasons (e.g. sensor fault), will not record measurement values, then this situation will be presented on the graph as interruption in the measurement (Fig.
User manual - DATA RECORDER SRD-99 and cooperating software Prior to analysing recorded measurement results, read the current data recorded by devices. In order to download current data recorded by devices press the [Download data (RS 485)] button in the Devices tab in the Configuration menu, or insert the USB FlashDrive (PenDrive) with logged data to PC USB port and confirm the data download.
User manual - DATA RECORDER SRD-99 and cooperating software Fig. 3.13. Configuration menu (advanced options active) 3.3.1. „ Devices ” tab Fig. 3.14. Configuration - Devices tab (advanced options active)
Page 94
User manual - DATA RECORDER SRD-99 and cooperating software The Devices tab (Fig. 3.14) contains such elements (fields) as: • Installed devices - shows the tree contains a list of all currently installed devices together with their addresses. The first level of the tree shows individual devices.
Page 95
User manual - DATA RECORDER SRD-99 and cooperating software Fig. 3.15. Devices adding and removing (advanced options active) Downloading of registered data Downloading of data stored on internal memory can be done in two ways: • using USB FlashDisk (PenDrive) •...
Page 96
User manual - DATA RECORDER SRD-99 and cooperating software To download data again enter Advanced Settings (password is required), then disable Auto option and select date of the begin of required data (Fig. 3.16). After that click [Download data (RS485)] button.
User manual - DATA RECORDER SRD-99 and cooperating software Fig. 3.17. Contents of Loggy Soft measurement data folder 3.3.2. „Groups” tab - group operations Fig. 3.18. Configuration - Groups tab A group enables creating a collective current graph/report for a number of measurement channels belonging to the same or to different devices, which the user wishes to view on one graph/report.
Page 98
User manual - DATA RECORDER SRD-99 and cooperating software Typical methods of grouping measurement channels: • measurement channels recording the measurements of the same physical value (e.g. temperature or humidity), • measurement channels recording the measurements from sensors located in the same places, e.g.
User manual - DATA RECORDER SRD-99 and cooperating software 3.3.3. „ Settings ” ta b Fig. 3.19. Configuration - Settings tab (advanced options hidden) Settings tab (Fig. 3.19) allows to change settings related to serial port and method of data downloading from the USB FlashDisk.
Page 100
User manual - DATA RECORDER SRD-99 and cooperating software • Time between automatic download field - this field specifies the time interval between automatic download new data from data loggers. This time can be set with precision to one minute, but can't be longer than 23 hours and 59 minutes. The...
User manual - DATA RECORDER SRD-99 and cooperating software 3.4. LIST OF ERRORS AND FAULT DIAGNOSTICS Symptom Cause Action All points are a red colour converter fault or one of • check converter power supply and a question mark (?) is converter's connections •...
User manual - DATA RECORDER SRD-99 and cooperating software III. USER MANUAL FOR “ S-TOOLKIT ” System requirements: At least i486 computer, Colour monitor with minimum resolution of 640 x 480, 1 MB of free hard drive space. Designed for Windows tested on Windows ®...
User manual - DATA RECORDER SRD-99 and cooperating software 3. USING PROGRAM Read current settings from device, from file or import settings from flash disk Write configuration set to device, to file or export settings to flash disk Fig. 3.1. Program main window...
User manual - DATA RECORDER SRD-99 and cooperating software [Export] • - saves the settings shown in the Inputs settings tab and writes the configuration set to the FlashDrive; [Close] • - exits the program. Status information concerning currently performed operation is shown in the bottom of the window.
User manual - DATA RECORDER SRD-99 and cooperating software detailed description available device configuration methods CONFIGURATION MODES section. In the central part of the tab (in a separated panel) there are fields for configuring device parameters. The parameters can be configured in three modes. Detailed description of individual parameters can be found in the user manual for device.
User manual - DATA RECORDER SRD-99 and cooperating software Logging options • - in this section define recording-related parameters for all recorded measurement channels of the device. • ”Logging setup” tab is available for devices equipped with data logging function, •...
Page 107
User manual - DATA RECORDER SRD-99 and cooperating software There are two buttons in the lower part of the tab: • [Lock write to device] - lock the possibility of writing configuration registries of the device through the RS-485 interface;...
User manual - DATA RECORDER SRD-99 and cooperating software 3.5. “ DEVICE INFORMATION” TAB Erasing device memory Updating device firmware Fig. 3.6. Device information tab options This tab has three sections: • Device - this section displays information concerning the device type and current version of device firmware.
User manual - DATA RECORDER SRD-99 and cooperating software Informations in Device and Memory sections are being updated while reading, writing or synchronizing date and time of the unit. 3.6. CONFIGURATION MODES Depending on the option selected in Configuration mode section of Inputs settings tab three methods of configuring the device are available.
User manual - DATA RECORDER SRD-99 and cooperating software 3.7. UPDATING DEVICE FIRMWARE The Firmware update section in the Device information tab enables device software update. To update the software: press the [ Update ] button. During update process the application attempts to reset the unit.
Page 111
User manual - DATA RECORDER SRD-99 and cooperating software...
Need help?
Do you have a question about the SRD-99 and is the answer not in the manual?
Questions and answers