Wiring Schematic - Master Spas H2X Owner's Manual

Hide thumbs Also See for H2X:
Table of Contents

Advertisement

07MS H2X Owners Manual
WIRING SCHEMATIC - 240 VOLT SWIM SPA HOOK-UP
Balboa
Instruments
Incorporated
Wire Key
Green (Ground)
Red (Hot)
Black (Hot)
White (Neutral)
House Breaker Box
BLK (HOT)
RED (HOT)
* Actual wiring of GFCI will vary by manufacturer of GFCI.The GFCI shown is a Square D.
Improper wiring of GFCI may result in permanent damage to the swim spa system box.
Repair /replacement of swim spa system box is not covered under warranty when damage
results from improper wiring.
1/10/07
11:29 PM
G.F.C.I Breaker Box
GRN (GROUND)
WHT
RED (HOT)
GRN
BLK (HOT)
14
Page 14
Swim Spa System Box
GRN (GROUND)
BLK (HOT)
WHT
RED (HOT)
WHT (NEUTRAL)
TB1
1
2
WHITE (NEUTRAL)
3
BLACK (HOT)
4
RED (HOT)
5
GREEN (GROUND)
NOTE: For a 240 V
dedicated hook-up, the
white neutral wire is
not required between
the G.F.C.I. and the
system box.
IDF00007.mac 6/17/97