Pin No.
Pin Name
DIS CHG
48
(WAKE UP)
49
WDT
50
WAKE UP
BATT POWER
51
FAIL
52
SS IRQ
53
RESET
54
XT1
55
XT2
56
VSS1
57
CF1
58
CF2
59
VDD1
60
AN0
61
CHARGE DET
62
AN2
63
SS SPI DOUT
64
SS SPI DIN
I/O
O
Wakeup control signal output "L" output when discharge
I
Watch dog timer reset signal input terminal
I
Wakeup control signal input "H": wakeup
I
Battery power fail detection signal input
I
Interrupt request signal input from the RF unit (RF61)
System reset signal input from the reset signal generator (IC123) "L": reset
I
For several hundreds msec. after the power supply rises, "L": is input, then it changes to "H"
I
Sub system clock input terminal (32.768 kHz) Not used (fixed at "H")
O
Sub system clock output terminal (32.768 kHz) Not used (open)
Ground terminal
I
Main system clock input terminal (6 MHz)
O
Main system clock output terminal (6 MHz)
Power supply terminal (+3.3V)
I
Not used (open)
I
Charge detection signal input "L": charge on
I
Not used (open)
O
Serial data output to the RF unit (RF61)
I
Serial data input from the RF unit (RF61)
Description
"H": reset Not used (fixed at "L")
"L": battery power fail
"L" active
SPP-A2770
45

Advertisement

Table of Contents
loading

Table of Contents