Advertisement

3.3 System Menu 2
TIME ADJUST: Selects internal clock or
external clock (UTC clock). Default setting
is INTERNAL.
For INTERNAL, set current day, month,
year, hour, minute and second with [+], [-],
[ ] or [ ] key. The setting clock appears
and it counts upward.
If EXTERNAL is selected, the screen
changes as follows.
TIME DIFFERENCE: Selects auto (UTC)
or manual. Auto uses the time difference in
ZDA (IEC 61162-1). In manual, it is
necessary to enter the time difference in
hours and minutes.
3.4 System Menu 3
RANGE 1- 8:
Activates or deactivates
specific range scales. Default ranges are 5,
10, 20, 40, 100, 200, 400, and 800 (meters).
Setting area is 2 m to 800 m. The ranges 20m
and 200 m can not be changed. They are
essential in this equipment.
Note:
Ranges must be set in numerical order.
For example, if range 1 is 5 m and range 3 is
20m, range 2 should be between 6 and 19 m.
Trend:
The trend index shows the probable
bottom shape over a specified time within
1-10 minutes. The default setting is 1 minute.
Set the Trend time with [+] or [-].