BRAVILOR BONAMAT Type I CHILL-003 Operating Instructions Manual

BRAVILOR BONAMAT Type I CHILL-003 Operating Instructions Manual

Chiller

Advertisement

Quick Links

CHILLER
WATER DISPENSER
Type I / Type II
Operating Instructions
Type I
Type II
This document is applicable to the model numbers:
D CHILL−003
D CHILL−004
www.bravilor.com

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Type I CHILL-003 and is the answer not in the manual?

Questions and answers

Summary of Contents for BRAVILOR BONAMAT Type I CHILL-003

  • Page 1 CHILLER WATER DISPENSER Type I / Type II Operating Instructions Type I Type II This document is applicable to the model numbers: D CHILL−003 D CHILL−004 www.bravilor.com...
  • Page 2  2013 Bravilor Bonamat All rights reserved. No part of this document may be reproduced and/or published by means of print, photoprint, microfilm or any other means without prior written permission from the manufacturer. The foregoing applies also to the figures and/or diagrams contained herein. The information provided in this document is based on general data that we were aware of at the time of publication, relating to constructions, properties of materials and working methods, and this document is therefore subject to modifications.
  • Page 3: Pictograms And Symbols

    Children must not to play with the apparatus. WARNING n Work on and repairs to the electrical system and the cooling system are strictly reserved for service engineers with the appropriate authorisation and training. ECopyright Bravilor Bonamat B.V.
  • Page 4: Table Of Contents

    ............Display messages and their meaning ......ECopyright Bravilor Bonamat B.V.
  • Page 5: Introduction

    Drip tray Condenser Power outlet inlet connector Cold water tank drain + water level Rubber foot PCB control box Water filter head Water source inlet Water filter bottle optional Fig. 1 Principal components and Control organs ECopyright Bravilor Bonamat B.V.
  • Page 6: Technical Data

    : normal, non−abrasive or corrosive detergent. Liquid disinfectants for the : CoolerClean Rinse (www.coolerclean.com) cold−water reservoir and outlet hydrogen peroxide solution (5%) CAUTION! − Before use, first read the instructions on the packaging of the cleaning agent. ECopyright Bravilor Bonamat B.V.
  • Page 7: Installation

    D Connect the device to the electricity supply to ensure a continuous supply of electricity. This maintains the operation of the cooling system and the water filter’s counter remains active. D Ensure that the device is correctly earthed. ECopyright Bravilor Bonamat B.V.
  • Page 8: Filter Installation And Replacement (Optional)

    D Wait approx. 3 minutes until the reservoir has filled. D Clean your Chiller following §5.2 (Flushing the water system) D Now only remove the plug from the socket for maintenance repairs or long periods of inactivity. ECopyright Bravilor Bonamat B.V.
  • Page 9: Everyday Usage

    D Place a cup under the water outlet and press the cold water button to draw off a refreshing cup of cold water. D Place a cup under the water outlet and press the sparkling water button to draw off a refreshing cup of sparkling water (Type II only). ECopyright Bravilor Bonamat B.V.
  • Page 10: Maintenance By Specially Autorized Personnel

    9. Again, use button 2 to draw off approximately 8.45 fl oz of water. 10. If a water filter is connected it should also be replaced now (see § 3.2.3). 11. Reset the timer for cleaning (see § 6.1.2). The device is ready for use. ECopyright Bravilor Bonamat B.V.
  • Page 11: Chiller (Type Ii)

    − Ensure that there is always at least one spare water filter in stock. − Clean the ventilator and the outside of the condenser every year (if necessary with a vacuum cleaner). CAUTION! − The remaining maintenance activities are strictly reserved for specially trained service engineers for cold−water systems. ECopyright Bravilor Bonamat B.V.
  • Page 12: Programming

    D the operation button light in front will flash. Reset function The signaling message won’t be lost until the filter is replaced and the counter is reset to zero. You can press the ”Reset” button once to reset it. ECopyright Bravilor Bonamat B.V.
  • Page 13: Protection Function

    ”E1” protection function When something is wrong with the temperature sensor or a connection loose, the digital display will show ”E1”. The device will stop working by control system unless the fault I has been solved. ECopyright Bravilor Bonamat B.V.
  • Page 14: Correcting Malfunctions

    Switch off electricity and water dispense any water and frozen. supply. Place the device in a warm the display remains on area (48 hours). 1C. Never use a hairdryer or anything similar to defrost the chiller. ECopyright Bravilor Bonamat B.V.
  • Page 15: Display Messages And Their Meaning

    Display messages and their meaning DISPLAY MESSAGES Cause/Action of the system: Action by the user: “E1” Something wrong with the temperature. Call in service. ECopyright Bravilor Bonamat B.V.
  • Page 16 © 05−2014...

This manual is also suitable for:

Type ii chill-004

Table of Contents