Removal Of Electrical Box - Daikin FTXL20G2V1B Service Manual

Heat pump/indoor/outdoor units, inverter pair wall mounted type g-series
Hide thumbs Also See for FTXL20G2V1B:
Table of Contents

Advertisement

Outdoor Unit - RXL20G2V1B9
3.2

Removal of Electrical Box

Procedure
Step
1
Disconnect the
connector for the
overload protector
[S40].
2
Disconnect the
connector for the four
way valve coil [S80].
3
Disconnect the 2
connectors for the
reactor.
192
Warning
Be sure to wait 10 minutes or more after turning off all power supplies
before disassembling work.
Procedure
SiENBE04-925_A
Points
Preparation
„ Remove the panels and
disconnect the connector for
the fan motor according to
the "Removal of Outer
Panels / Fan Motor".
[S40]
(R11846)
[S80]
(R11848)
(R11844)
Removal Procedure

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents