13. AUTO RESTART

When the power was interrupted by a power failure, etc. during operation, the operation contents
at that time are memorized and when power is recovered, operation is automatically started with
the memorized operation contents.
When the power is interrupted and recovered during timer operation, since the timer operation time
is shifted by the time the power was interrupted, an alarm is given by blinking (7 sec ON/2 sec OFF)
the indoor unit body timer lamp.
[ Operation contents memorized when the power is interrupted ]
Operation mode
Set temperature
Set air flow
Set air flow direction
Swing
Economy operation
10°C Heat operation
Thermistor detected position
Timer mode
*It is necessary to set on the DIP-SW1-No,6 of the wired remote controller, to enable the memory backup.
Refer to the installation manual of wired remote controller for details.
14. MANUAL AUTO OPERATION (Indoor unit body operation)
If MANUAL AUTO Button is set, the operation is controlled as shown in Table 13.
If the remote control is lost or battery power dissipated, this function will work without the remote control.
(Table 13)
OPERATION MODE
FAN CONT. MODE
TIMER MODE
SETTING TEMP.
SETTING LOUVER
SWING

15. FORCED COOLING OPERATION

If cooling operation is set, the operation is controlled as shown in Table 14.
( Table 14 )
OPERATION MODE
FAN CONT. MODE
TIMER MODE
SETTING TEMP.
SETTING LOUVER
SWING
Forced cooling operation is started when pressing MANUAL AUTO button for 10 seconds or more.
During the forced cooling operation, it operates regardless of room temperature sensor.
Operation LED and timer LED blink during the forced cooling operation. They blink for 1 second ON
and 1 second OFF on both operation LED and timer LED (same as test operation).
Forced cooling operation is released after 60 minutes of starting operation.
The FORCED COOLING OPERATION will start as shown in Table 14.
Wired RC
Wireless RC
(Memory Backup : Disable)

Manual auto operation

Auto changeover
Auto
Continuous (No timer setting available)
24°C
Standard
OFF
Forced cooling operation
Cooling
Hi
-
Room Temp is not controlled
Initial : Horizontal
(It is changed follow as setting of remote controller)
OFF
Wired RC
(Memory Backup : Enable)
OFF Timer
ON Timer
WEEKLY Timer
Temperature
SET BACK Timer
: Memorize
: Not memorize
01-15