Fujitsu ARY36FUAN Service Manual page 3

Duct type (50hz)
Table of Contents

Advertisement

TYPE
INDOOR UNIT
OUTDOOR UNIT
NOISE LEVEL
HI-SPEED
INDOOR UNIT
MED-SPEED (dB)
LO-SPEED
OUTDOOR UNIT
Note : Static pressure : 100Pa
Duct length : Inlet 1m, Outlet 2m
REFRIGERANT CHARGE (R410A)
MAX PIPE LENGTH / HEIGHT
PIPE LENGTH
20 m
25 m
30 m
FULL CHARGE
AMOUNT
35 m
40 m
45 m
50 m
ADDITIONAL REFRIGERANT
COOLING
ARY36FUAN
AOY36FNAXT
(dB)
(dB)
(dB)
54
(m)
2,000 g
2,150 g
2,300 g
2,450 g
2,600 g
2,750 g
2,900 g
- 2 -
COOLING & HEATING
ARY36UUAN
AOY36UNAXT
43
41
39
COOL 54 / HEAT 55
50 / 30
3,200 g
3,350 g
3,500 g
3,650 g
3,800 g
3,950 g
4,100 g
30 g/m