Elsner AQS/TH PF Installation And Adjustment Manual

Indoor sensor and ventilation control

Advertisement

Quick Links

EN
AQS/TH PF
Indoor Sensor and Ventilation Control
Item number 40115
Installation and Ad justment

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the AQS/TH PF and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Elsner AQS/TH PF

  • Page 1 AQS/TH PF Indoor Sensor and Ventilation Control Item number 40115 Installation and Ad justment...
  • Page 3: Table Of Contents

    5.2. Manual operation ....................24 5.2.1. Key functions ....................24 5.3. Operation modes ....................25 Elsner Elektronik GmbH • Sohlengrund 16 • 75395 Ostelsheim • Germany Ventilation Control AQS/TH PF • from software version 1.0 Status: 31.01.2017 • Subject to technical changes. Errors excepted.
  • Page 4 The change status (software version and date) can be found in the contents footer. If you have a device with a later software version, please check www.elsner-elektronik.de in the menu area "Service" to find out whether a more up-to- date version of the manual is available.
  • Page 5: Description

    (rain detector or similar) takes precedence. The housing fits into standard 55 mm switching programmes and is available in two different colours. The AQS/TH PF is equipped with two buttons for manual control of the respective window/ventilator and for adjusting the device. The display shows current measured values and mode and guides through the set-up menus.
  • Page 6: Measuring Accuracy

    When measuring temperature, the self-heating of the device is considered by the electronics. The heating is compensated by reducing the measured temperture by the self-heating of 0.7°C. The indicated indoor temperature measured value approches the Ventilation Control AQS/TH PF • Version: 31.01.2017 • Technical changes and errors excepted.
  • Page 7: Installation And Start-Up

    Elsner Elektronik is not liable for any changes in norms and standards which may occur after publication of these operating instructions.
  • Page 8: Sensor Connection And Design

    2.3. Sensor connection and design 2.3.1. Housing Fig. 1 Base plate Catches Openings for air circulation CLOSE/- button CLOSE/- LED (recessed) OPEN/- LED (recessed) OPEN/- button Openings for air circulation (LOWER) Ventilation Control AQS/TH PF • Version: 31.01.2017 • Technical changes and errors excepted.
  • Page 9: Connection Board

    Supply voltage for output 1+2 black Input 2 (OPEN/+) yellow Input 1 (CLOSE/-) black Supply voltage for input 1+2 white Operating voltage GND black Operating voltage +24 V Ventilation Control AQS/TH PF • Version: 31.01.2017 • Technical changes and errors excepted.
  • Page 10: Wiring Diagram Window

    Installation and start-up 2.3.3. Wiring diagram Window Fig. 4: With relays Ventilation Control AQS/TH PF • Version: 31.01.2017 • Technical changes and errors excepted.
  • Page 11: Wiring Diagram Ventilation Units

    Installation and start-up 2.3.4. Wiring diagram Ventilation Units Fig. 5 With Relays Ventilation Control AQS/TH PF • Version: 31.01.2017 • Technical changes and errors excepted.
  • Page 12: Wiring Diagram Smoke And Heat Extraction System

    2.5. Notes on mounting and commissioning Never expose the device to water (e.g. rain) or dust. This can damage the electronics. You must not exceed a relative humidity of 95%. Avoid condensation. Ventilation Control AQS/TH PF • Version: 31.01.2017 • Technical changes and errors excepted.
  • Page 13: Basic Setting

    Settings Select "Drive". You can change the selection using the left/right keys. Auto Drive  Press both keys, let go when the LEDs light up Ventilation Control AQS/TH PF • Status: 31.01.2017 • Technical Changes and Errors excepted.
  • Page 14 You may choose between German and English as display languages. Language You can change the selection using the left/right keys.  Press both keys, let go when the LEDs light up Ventilation Control AQS/TH PF • Status: 31.01.2017 • Technical Changes and Errors excepted.
  • Page 15 Select whether a window or ventilator is connected. You can change the selection using the left/right keys. controls Window Vent.  Press both keys, let go when the LEDs light up Ventilation Control AQS/TH PF • Status: 31.01.2017 • Technical Changes and Errors excepted.
  • Page 16 Use the right/left keys to increase or decrease the time < 65 sec > respectively (range 1...300 seconds). Press both keys, let go when the LEDs light up Ventilation Control AQS/TH PF • Status: 31.01.2017 • Technical Changes and Errors excepted.
  • Page 17 > respectively (range 5...120 minutes). Select "do not use" if you prefer to have no automatic reset. Press both keys, let go when the LEDs light up Ventilation Control AQS/TH PF • Status: 31.01.2017 • Technical Changes and Errors excepted.
  • Page 18: Adjust Automatic Ventilation System

    • To save modifications and return directly to the standard page, press both buttons for a while until the standard page appears. Ventilation Control AQS/TH PF • Status: 31.01.2017 • Technical Changes and Errors excepted.
  • Page 19 Modify the selected (underlined) digit Press the right or left key for some time Advance to the next point Press both keys, let go when the LEDs light up Ventilation Control AQS/TH PF • Status: 31.01.2017 • Technical Changes and Errors excepted.
  • Page 20 You can change the selection using the left/right keys. If you select "no", the following temperature settings shall  not be displayed. Press both keys, let go when the LEDs light up Ventilation Control AQS/TH PF • Status: 31.01.2017 • Technical Changes and Errors excepted.
  • Page 21 2. The values for step 2 should be higher than for step 1. Avoid overlaps. Press both keys, let go when the LEDs light up Ventilation Control AQS/TH PF • Status: 31.01.2017 • Technical Changes and Errors excepted.
  • Page 22 < 50 % > < 50 % > the window or switches off the ventilator. Press both keys, let go when the LEDs light up Ventilation Control AQS/TH PF • Status: 31.01.2017 • Technical Changes and Errors excepted.
  • Page 23 You can change the selection using the left/right keys. If you select "no", the following air CO settings shall not be  displayed. Press both keys, let go when the LEDs light up Ventilation Control AQS/TH PF • Status: 31.01.2017 • Technical Changes and Errors excepted.
  • Page 24 2. The values for step 2 should be higher than for step 1. Avoid overlaps. Press both keys, let go when the LEDs light up Ventilation Control AQS/TH PF • Status: 31.01.2017 • Technical Changes and Errors excepted.
  • Page 25: Use Of The Device, Manual Airing

    605 ppm 580 ppm Priority 0% Auto 0 Priority mode, Frost protection active window closed ventilator off, When frost protection is completed, the device switches to automatic Ventilation Control AQS/TH PF • Status: 31.01.2017 • Technical Changes and Errors excepted.
  • Page 26: Manual Operation

    In priority mode and when frost protection is activated, manual operation (and automatic mode) are blocked.  Operation modes, page 25 5.2.1. Key functions The following applies for the integrated buttons of the AQS/TH PF and for the buttons/ actuators connected to the inputs: Window Ventilator speed...
  • Page 27: Operation Modes

    LEDs light up Priority mode It is possible to make a priority switch via the AQS/TH PF inputs: If a signal is issued for more than 3 seconds at an input, this command takes priority. Manual operation and automatic mode are blocked.
  • Page 28  Frost protection, page 15 Frost protection switches off automatically when the temperature rises above 9°C. The AQS/TH PF then returns to the mode displayed. If that should be manual mode, the window remains closed or the ventilator switched off.
  • Page 30 Elsner Elektronik GmbH Control and Automation Engineering Sohlengrund 16 75395 Ostelsheim Phone +49 (0) 70 33 / 30 945-0 info@elsner-elektronik.de Germany +49 (0) 70 33 / 30 945-20 www.elsner-elektronik.de Technical support: +49 (0) 70 33 / 30 945-250...

This manual is also suitable for:

40115

Table of Contents