Page 2
This document is protected by copyright law. Copying or duplicating be it physically or electronically for any usage other than the operation of a Nauticast B2 AIS System is prohibited and any offender may be liable to the payment of damages.
PC .................... 8 NSTALLING THE SOFTWARE ONTO YOUR ’ ..........................8 NTER YOUR SHIP S DATA 2.4.1 Connecting the Nauticast B2 to your PC ....................... 8 2.4.2 Configuring Software and Nauticast B2 static data ..................10 ......................12 NSTALLING YOUR AUTICAST HARDWARE 2.5.1 Installation hints ............................
Page 4
Safety of Life Systems Nauticast devices may only be used in safety of life devices or systems with the express written approval of Nauticast. The unsolicited and untested use of Nauticast devices in safety of life devices or systems may jeopardize the safety or the life of the user or other persons.
A "polling or controlled" mode, where data transfer occurs in response to polling from a ship or entitled authority. This illustration depicts a typical AIS System where two or more AIS equipped vessels (and shore based systems) are automatically communicating with each other: Page 5 of 32 B2 Product Manual 2_0...
The illustration below depicts a typical Nauticast B2 installation in a common environment. When the Nauticast B2 is connected to the vessel’s power supply and both VHF and GPS antenna it fulfils the requirement for standard operation. The scenario shows a full AIS coverage area (including all applications and complete shore infrastructure).
The marine AIS system uses position information derived from networks such as the Global Positioning Satellite (GPS) or the Global Navigation Satellite System (GLONASS) in order to determine the location of the AIS unit and thus the vessel to which it is fitted. The Nauticast B2 utilizes the GPS satellite network.
2.4 Enter your ship’s data NOTE: To program your Nauticast B2 you will need to connect it to a personal computer or a notebook with the Link2AIS software installed. There is no external power source needed when using a USB connection.
Page 9
The serial port (port number can be found in the device manager of Windows) can also be selected manually from the menu. Click 'Save' when the right port is selected. For the Nauticast B2 115200 bps need to be used. ...
2.4.2 Configuring Software and Nauticast B2 static data The functions of Link2AIS are arranged in a series of menus. Depending on the version of Link2AIS installed not all menu entries shown below may be visible. Open ‘AIS Settings’ - ‘Identification’. This will display the 'Static Data' for the connected transponder.
Page 11
For connecting a Chart Plotter please refer to section 3 “ Connecting external equipment”. For additional information about the Link2AIS software please refer to the Link2AIS Software User Guide (‘Help – Link2AIS-Help’, section Documentation). Page 11 of 32 B2 Product Manual 2_0...
When attaching other parts to the system follow the technical recommendations in section 4.3 “Using different antennas”. Do not connect the Nauticast B2 unit to a main line 110/220V AC electrical supply, as it could cause electric shock or fire. Only use 12-24V DC power sources! ...
DC power lead (red = positive, black = negative) and plug the power connector into the Nauticast B2. Please see the Appendix B of this manual for details of the power, data and RF cables supplied. 2.5.4 Mounting the Nauticast B2 Attach the mounting plate with Phillips self tapping head screws (10-32 x 1,2) on a vertical surface.
3.5 External LED status indicators (optional data cable required) If the Nauticast B2 is not visible and the status LEDs should still be monitored, external LEDs can be connected with Cable 4 of the optional Data Cable (prod. no.: 3001004). (see Appendix B for more details).
Operation of your Nauticast B2 4.1 Interpreting Status LEDs Please note that a proper 12 / 24 VDC power suppply is necessary for the B2 to operate flawlessly. The USB connection will not suffice! All Class B Devices and hence the Nauticast B2 have a lower priority than Class A devices and base stations whenever the AIS-channel is highly loaded.
If other antennas are being used, please take note of the following minimal requierements: 4.3.1 GPS Antenna The Nauticast B2 has a TNC female bulkhead connector. This port provides a 5V DC feed for an active GPS antenna, required by the Nauticast B2 unit (i.e. it should incorporate an LNA). Therefore, the GPS antenna must be an active type using 5V.
DCS communication. 4.4 Standards The Nauticast B2 complies with all standards under the European R&TTE directive Article 3.1(a), 3.1(b), 3.2 and 3.3(e). Among other, these standards have been implemented: IEC 62287-1: 2006-03 Maritime navigation and radio communication equipment and systems –...
USB power supply alone! Transmissions by any class B device, and therefore also the B2, are subject to available time slots in the broadcast area of the device; e.g. a command received by Message 23 or a large number of...
Appendix 8.1 APPENDIX A – Block Diagram System Block Diagram (Note: Mount your unit with cable/connector side down) Power supply, PC, NMEA compatible devices not included Data Cable optional Page 19 of 32 B2 Product Manual 2_0...
Use of the Data Cable (Part No. 300 1004) CABLE 1: Connect the appropriate cable ends to the designated NMEA 0183 device (Baud rate 38400). Wire end Nauticast B2 Possible end of attached NMEA device RS422 TX A, yellow connect to...
Page 21
The input voltage of the alarm relay is matched with the operating voltage of the Nauticast B2. The operating voltage of the alarm relay is 3 to 60 VDC with a load current of 0.1 to 2 A (3A when using a heat sink).
Page 22
Connection of the Alarm Relay CABLE 4: Depending on the Voltage used for the Nauticast B2 you have to calculate the series resistor which is connected with the LED between the + wire (grey) and the OUTPUT wire (CH1 LED RED, green;...
(off) (off) green 1. MMSI not programmed or Program valid MMSI into B2, using invalid MMSI the Link2AIS software provided 2. VHF or GPS Antenna connection a. Check antenna connectors on is faulty both ends (2 for VHF, 2 for GPS);...
Page 29
If the problem remains unsolved after completing the instructions above, we kindly ask you to contact Nauticast Support with a log file (ideally: 2-3 hours of voyage) of your Nauticast B2 in operation. To create the log: ...
Page 32
For more information and the latest updates visit us at www.nauticast.com Nauticast GmbH Lützowgasse 12-14 / 3.OG 1140 Vienna, Austria T: +43 (1) 5 237 237-0 F: +43 (1) 5 237 237-150 office@nauticast.com...