Standard Repair Process Detail Technical Manual
Error
Established
error_No
A. Video
video/Normal audio
symptom
date
Revised
Content
Check Vx1 lock
A1
date
R7624 : 0[V]
Check a voltage of R7624 after turn on the TV.
If the voltage is low, Vx1 is locked.(OK)
A1