plate is located directly above the required
drilling location.
Fasten the drill stand.
Setting the drilling angle
Loosen the clamping lever 17.
Push in or pull out the rod 15 until the
desired drilling angle is shown on the scale.
Tighten the clamping lever 17.
Drilling
Always ensure a adequate anchorage in the
underground.
Open the water tap 7.
Actuate the ON/OFF switch 2.
Drill using an even forward feed. Do not over-
load the machine.
The leaking water should be milky and not
clear.
Always loosen the locking screw 16 (BCR
130/5-164/6,5) or the clamping lever 35 (BCR
300/12) when drilling.
After drilling switch the machine off and shut
off the water tap.

DRILL STAND FIXATION

CAUTION: The drill stand must
always be mounted firmly and
must not be able to move during
drilling.

Secure using assembly

Drill the rawlplug hole Ø 15/16 mm (see
instruction rawlplug).
Insert rawlplug. SD M12
Screw in assembly 25.
Align the drill stand.
Fasten the drill stand with the spindle nut 24.

Vacuum pump fixation

Setting up the vacuum pump
Position the machine horizontally. Maximum
tilt of 10°.
Fasten, mount suction hose 42 and fasten
with hose clip 41.
12
BEAST CORE RIG OPERATING MANUAL
®
BCR130/5-BCR164/6,5-BCR300/12
WARNING: Maximum drilling diam-
eter of 100 mm. Mount the drill
stand on an even, firm and smooth
surface using the vacuum pump,
never "over" head. Always connect
the core drill and the vacuum pump
to the same power outlet. Never
turn off the vacuum pump during
operation.
Install the vacuum kit.
Turn the fixation screws 21 ensuring, how-
ever, that the seal 29 is not squeezed.
Align the drill stand.
Mount the suction hose to the connection for
the vacuum pump 27.
Close the ventilating tap 28.
Connect quick coupling 43 to vacuum kit 27
on the drill stand.
The machine has no On/Off switch; it is put
into operation by inserting the mains plug 45
into the socket.
The existing vacuum can be read from the
vacuum gauge 40.
The vacuum gauge 40 must show a vacuum
of below -0.65 bar. If not check for leakage.
Do not commence work until the required
vacuum has been reached.
Watch the vacuum gauge 40 while working.
If the vacuum rises above -0.65 bar, inter-
rupt the work immediately and completely
remove the drill stand.
Empty the fluid collecting container 44
If fluid is sucked in during operation, the
vacuum will no longer be maintained. Pull
the mains plug out immediately.
Unscrew the fluid collecting container 44.
Remove the float and empty the container.
Replace the float and screw on the container
tightly again.
CAUTION: The machine becomes
hot after a long period of use. Do
not touch the machine directly
after operating it.